Service Manual
Bosch Climate 5000 Series Ductless Air Conditioner / Heat Pump Multi Zone Outdoor Units (01.2023)
4. Disconnect the fan motor connector CN14 from the IPM board.
Figure 119
5. Remove the four fixing screws of the fan motor. Then remove the fan motor.
Figure 120
9.2.3 Removing the electrical parts
1. Follow steps outlined in Section 9.2.1 & 9.2.2.
2. Remove the screws of the IPM board (4 screws).
Figure 121
IPM board
3. Disconnect the connector to reactor from PCB.
Figure 122
PCBboard
4. Disconnect the compressor wire.
Figure 123