EasyManua.ls Logo

Bosch C 1210 ESC - Dimensions and Minimum Installation Clearances

Bosch C 1210 ESC
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Data subject to change without notice | 01.2011
BOSCH THERMOTECHNOLOGY CORPORATION
THERM Tankless Water Heater Applications Manual
10
|
0
1
2
3
4
5
6
7
8
520 PN/HN
330
P
N
10 20 30 40 50 60 70 80 90
Degree rise (°F)
GPM
Gas Appl
i
ance S
i
z
i
n
g
Char
t
940 ES
/
ESO
C 1050 E
S
9
10
C 1210 ES
/
ES
C
11
830
E
S
660 EF
/
EFO
12
Flows above 10 GPM assume installation of a mixing valve to
help mitigate pressure drop in the water heater and plumbing
system