6 720 607 884 (2009/05) GB
WR8..P...
WR11..P...
With piezo ignition and double safety system
consisting of flue gas monitor and heat
exchanger temperature sensor.
Safety instructions:
If you smell gas:
- Do not operate any electrical switches.
- Do not telephone from inside the danger area.
- Turn off the gas cock.
- Open windows and ventilate room.
- From outside, call the gas company and your approved
installer.
Do not use or store easily combustible materials in the vicinity
of the appliance.
Gas Instantaneous Water Heater
Installation Manual and Operating Instructions
Installation and servicing of the appliance may only be
carried out by an approved technician.
The appliance should be regularly serviced in order to ensure
that it remains in perfect and safe working order.
If there is a risk of freezing, the appliance must be switched
off and drained. If the appliance has not been drained during
a cold spell, when it is switched on again check that it
produces hot water. If problems occur, contact your installer

Other manuals for Bosch WR11 series

Questions and Answers:

Bosch WR11 series Specifications

General IconGeneral
Fuel TypeNatural Gas or Propane
Gas Connection1/2" NPT
Water Connection1/2" NPT
IgnitionElectronic
Activation Flow Rate0.6 GPM
Power Supply120 VAC
TypeTankless

Summary

Safety Instructions

Technical Characteristics and Dimensions

Dimensions

Provides detailed measurements (A, B, C, D, E, F, G, H) for WR8/11 models.

Appliance Design

Illustrates the internal components of the water heater with numbered parts.

Technical Characteristics

Details technical data for WR8 and WR11 models including output, pressure, and consumption.

Preconditions for Installation

Regulations

Highlights legal requirements for gas appliance installation by competent persons.

Location Requirements

Specifies ventilation, temperature, and corrosion prevention for installation site.

Water and Gas Connections

Details on connecting water pipes, including advice on non-return valves and gas inlet precautions.

Flue Installation

Essential requirements for gas-tight flue pipe connection and material specifications.

Commissioning

Steps for initial startup including leak checks and flue gas safety device verification.

Operation and Maintenance

Appliance Function and Ignition

Explains the piezo ignition system and main burner operation for hot water supply.

Water Temperature Control

How to adjust water flow rate and temperature using the control knob.

Maintenance and Servicing

Recommends professional servicing, overhaul checks, and use of genuine spare parts.

Purging the Appliance (Freeze Risk)

Procedure to drain the appliance to prevent damage from freezing.

Flue Gas Safety Device

Details on the safety device's function, reset, and troubleshooting.

Troubleshooting Common Problems

Table of common issues like pilot flame, low hot water, and flow rate with solutions.