2 Safety
Please read these instructions carefully before using the charger.
I
CAUTION
If the power supply cable is damaged, it must be replaced by the manufacturer or
service representative in order to avoid any danger.
Disconnect the power supply before making or breaking the connections to the bat-
tery.
The battery connection, which is not connected to the vehicle body, must be con-
black, away from the battery and fuel lines. Only then connect the battery charger to
the mains supply.
-
connect the connection to the vehicle body (–) black and battery connection (+) red
in this order.
I
WARNING
The mains plug must not come into contact with water. Water must be prevented from
I
WARNING
Danger of explosion and re!
Explosive gases.
Provide adequate ventilation during the charging process.
Ensure that the area around the battery is well ventilated during the charging pro-
cess.
Battery
Use the battery charger only for 12 V 5 Ah-120 Ah lead-acid type (WET, EFB, GEL, AGM,
open and VRLA) batteries.
I
WARNING
Do not attempt to charge a non-rechargeable battery!