Operation and maintenance
35
Climate 5000 M – 6721849820 (2022/11)
2.4 Information on refrigerant
This device contains fluorinated greenhouse gases as refrigerant. The
unit is hermetically sealed. The following information on the refrigerant
complies with the requirements of EU Regulation No. 517/2014 on
fluorinated greenhouse gases.
Notice for the user: If your installer adds refrigerant, he enters the added
fill volume and the total amount of the refrigerant in the following table.
Table 29 F-Gas
3 Operation and maintenance
CAUTION
Danger due to electric shock or moving parts
Disconnect the power supply before carrying out any maintenance
work.
Have any maintenance steps that are not listed here carried out by an
approved installer.
You can find information on operating the indoor units in the
corresponding operating instructions.
3.1 Operating mode conflict
When using multi-split air conditioners, all operating modes are
possible, but with the following special features:
If you operate more than one indoor unit, indoor units may go into
standby due to an operating mode conflict. An operating mode conflict
occurs when at least one indoor unit is in heating mode and at least one
indoor unit is in another operation mode at the same time (e.g. cooling
mode). Heating mode always has priority. All indoor units that are not in
heating mode go into standby due to the operating mode conflict.
Indoor units with operation mode conflict show “−−” in the display or the
ON indicator flashes and the timer indicator is on. See technical
documentation of the indoor unit for more information.
Avoid the operating mode conflict:
No indoor unit is in heating mode.
All indoor units are in heating mode and/or off.
Product type Rated cooling
output
[kW]
Rated heating
output
[kW]
Refrigerant
Type
Global
warming
potential
(GWP)
[kg Co
2
equ.]
CO
2
equivalent
of initial
charge
Initial
charge
volume
[kg]
Additional fill
volume for
pipe length
L
1)
[g/m]
1) Total pipe length L in metres (if L > 5 m simple path from outdoor unit to indoor unit).
Total charge
volume during
commissioning
[kg]
CL5000M 41/2 E 3.52 3.81 R32 675 0.49 0.72 12
CL5000M 53/2 E 5.28 5.57 R32 675 0.78 1.15 12
CL5000M 62/3 E 7.03 7.62 R32 675 1.01 1.5 12
CL5000M 79/3 E 8.79 9.38 R32 675 1.35 2.0 24
CL5000M 82/4 E 10.55 11.72 R32 675 1.62 2.4 24
CL5000M 105/4 E 10.55 11.72 R32 675 1.62 2.4 24
CL5000M 125/5 E 12.02 13.48 R32 675 1.89 2.8 24

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Climate CL5000M 79/3 E and is the answer not in the manual?

Bosch Climate CL5000M 79/3 E Specifications

General IconGeneral
BrandBosch
ModelClimate CL5000M 79/3 E
CategoryAir Conditioner
LanguageEnglish

Related product manuals