Batterydisplay, Battery in Charger
Indication Meaning Measure
When putting in charg-
er, display shows quan-
tity of previous recharg-
es for 1 minute, then
battery capacity with
bars filling.
Allow battery to
charge on 100 %.
Battery fully charged. Leave indefinitely
in charger, or re-
move and store or
use.
Display shows flashing
thermometer and bat-
tery symbol for
5minutes:
Battery is too hot
(between 50 °C
70 °C). Battery can
be used in tool, but
not be charged.
Battery is too cold
(under 0 °C)
Battery will not
charge until tem-
perature is within
limits:
Let battery
cool down
Let battery
warm up
No display shows:
Battery is too hot
(over 80 °C)
Battery is defective
–Charging can-
not start until
battery has
cooled down.
–Replace bat-
tery