30 | English
– Aim the laser at the closer wall A and al-
low the measuring tool to level in. Mark
the middle of the point at which the laser
lines cross on the wall (pointI).
– Turn the measuring tool 180°, allow it to
level in and mark the point where the
laser lines cross on the opposite wall B
(pointⅡ).
– Position the measuring tool –without rotating it– close to wallB, switch it on and al-
low it to level in.
– Align the height of the measuring tool
(using the tripod or by placing objects
underneath as required) so that the
point where the laser lines cross exactly
hits the previously marked pointⅡ on
wallB.
– Turn the measuring tool 180° without
adjusting the height. Aim it at wallA
such that the vertical laser line runs
through the already marked pointⅠ. Al-
low the measuring tool to level in and
mark the point where the laser lines
cross on wallA (pointⅢ).
– The discrepancy d between the two marked pointsⅠ and Ⅲ on wallA reveals the ac-
tual height deviation of the measuring tool.
1 609 92A 7AN | (14.12.2021) Bosch Power Tools