EasyManuals Logo

Bosch Integra 500 Series Technical Service Bulletin

Bosch Integra 500 Series
3 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Technical Service Bulletin:
Replacing Primary Fan & Main Burner
Models: C1210ESC, C1210ES, C1050ES, C950ES, 940ES, 940ESO, 830ES, 2400ES,
2700ES, 715ES, C800ES, C920ES/ESC, Integra 500, Evolution 500
Introduction
This procedure must be performed by a quali ed technician.
Tools needed:
Phillips head screwdriver
30mm open end wrench or large adjustable wrench
8mm open end wrench
Preparation
1. Use the power button on the front of the water heater to turn
the appliance off and then unplug from the electrical outlet.
Isolate the gas supply to the water heater by closing the
installer supplied gas shut-off valve.
2. Shut the inlet and outlet water supply off to the water heater
3. Drain the water from the water heater.
4. Loosen two Phillips head screws located at bottom rear of
cover. (Fig. 1, step 1).
5. Lift front cover upward and remove. (Fig. 1, step 2).
Step 1 Step 2
20644956-11.1V
Step 3Step
1
Step
2
2
0
6
44
9
56
-
11
.
V
Step
3
Figure 1
6. Remove combustion cover by unclipping two upper and two
lower clips securing cover. (Fig. 1, step 3)
7. Remove 3 Phillips screws on control unit (Fig. 2, step 1). Place
control unit into the service postion by engaging its tabs with
the holes in the horizontal sheet metal on bottom of the heater
chassis . (Fig. 2, step 2).
Step 2
Gas
Valve
S
te
p
2
Ga
s
V
a
l
ve
Figure 2

Other manuals for Bosch Integra 500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Integra 500 Series and is the answer not in the manual?

Bosch Integra 500 Series Specifications

General IconGeneral
BrandBosch
Model SeriesIntegra 500 Series
Activation Flow Rate0.5 GPM
TypeTankless
Temperature Range100°F to 140°F

Related product manuals