EasyManua.ls Logo

Bosch KUL15AFF0G - Page 25

Bosch KUL15AFF0G
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting en
25
Fault Cause troubleshooting
The LED lighting does not
work.
The illuminant is defective. 1. "Switch off the appliance."
→Page16
2. Disconnect the appliance from the
mains.
Unplug the appliance from the
mains or switch off the circuit
breaker in the fuse box.
3. Slide the cover grille forwards and
remove it.
4. Replace the illuminant.
Replacement illuminant: 220–240
V AC, E14 bulb holder, see the de-
fective illuminant'ss wattage.
The light switch is jammed.
Check whether the light switch can
be moved.
The refrigeration unit is
switching on more fre-
quently and for longer.
The appliance door was
opened frequently.
Do not open appliance door unne-
cessarily.
The ventilation openings are
covered up.
Remove any obstructions from in
front of the ventilation openings.
The base of the refrigerator
compartment is wet.
The condensation channel
or drainage hole are
blocked.
"Clean the condensation channel
and the drainage hole." →Page22