Technical Data
Noise/Vibration Information
Measured sound values determined according to EN 60745.
Typically the A-weighted noise levels of the product are:
Sound pressure level 85 dB(A); Sound power level 96 dB(A).
Uncertainty K =3 dB.
Wear hearing protection!
Vibration total values a
h
(triax vector sum) and uncertainty K
determined according to EN 60745:
Cutting board: a
h
=17.5m/s
2
, K=1.5 m/s
2
,
Cutting wooden beam: a
h
=17.5m/s
2
, K=1.5 m/s
2
.
The vibration emission level given in this information sheet
has been measured in accordance with a standardised test
given in EN 60745 and may be used to compare one tool with
another. It may be used for a preliminary assessment of expo-
sure.
The declared vibration emission level represents the main ap-
plications of the tool. However if the tool is used for different
applications, with different accessories or poorly maintained,
the vibration emission may differ. This may significantly in-
crease the exposure level over the total working period.
An estimation of the level of exposure to vibration should also
take into account the times when the tool is switched off or
when it is running but not actually doing the job. This may sig-
nificantly reduce the exposure level over the total working pe-
riod.
Identify additional safety measures to protect the operator
from the effects of vibration such as: maintain the tool and the
accessories, keep hands warm, organise work patterns.
Declaration of Conformity
We declare under our sole responsibility that the product de-
scribed under “Technical Data” is in conformity with the fol-
lowing standards or standardization documents: EN 60745
according to the provisions of the directives 2011/65/EU,
2004/108/EC, 2006/42/EC.
Technical file (2006/42/EC) at:
Robert Bosch GmbH, PT/ETM9,
D-70745 Leinfelden-Echterdingen
Robert Bosch GmbH, Power Tools Division
D-70745 Leinfelden-Echterdingen
Leinfelden, 29.04.2013
Assembly
Before any work on the machine itself (e.g. mainte-
nance, tool change, etc.) as well as during transport
and storage, remove the battery from the power tool.
There is danger of injury when unintentionally actuating
the On/Off switch.
Battery Charging (see figure B)
Use only the battery chargers listed on the accessories
page. Only these battery chargers are matched to the lith-
ium ion battery of your power tool.
Note: The battery is supplied partially charged. To ensure full
capacity of the battery, completely charge the battery in the
battery charger before using your power tool for the first time.
The lithium ion battery can be charged at any time without re-
ducing its service life. Interrupting the charging procedure
does not damage the battery.
The battery is equipped with a NTC temperature control
which allows charging only within a temperature range of be-
tween 0 °C and 45 °C. A long battery service life is achieved
in this manner.
Removing the battery
To remove the battery 8, press the battery unlocking button
11 and pull the battery out of the power tool toward the rear.
Do not exert any force.
Replacing/Inserting the Saw Blade
When mounting the saw blade, wear protective gloves.
Danger of injury when touching the saw blade.
When changing the saw blade, take care that the saw
blade holder is free of material residue, e.g. wood or
metal shavings.
Selecting a Saw Blade
An overview of recommended saw blades can be found at the
end of these instructions. Use only ½" universal shank saw
blades. The saw blade should not be longer than required for
the intended cut.
The shank thickness of the saw blade must be 0.81.6 mm.
Use a thin saw blade for narrow curve cuts.
Inserting the Saw Blade (see figure A)
Press the SDS clamping lever 4 forward and guide the saw
blade 1 behind the clamping plate 10 into the saw blade
holder 3. Release the SDS clamping lever 4.
Check the tight seating by pulling on the saw blade.
A loose saw blade can fall out and cause injury.
Sabre saw PSA 18 LI
Article number
3 603 CB2 3..
Rated voltage
V= 18
Stroke rate at no load n
0
min
-1
0–2800
Tool holder
SDS
Stroke rate control
Stroke
mm 22
Cutting depth, max.
in wood
in non-alloy steel
Pipe diameter
mm
mm
mm
100
20
20
Weight according to
EPTA-Procedure 01/2003
kg 2.3
Henk Becker
Executive Vice President
Engineering
Helmut Heinzelmann
Head of Product Certification
PT/ETM9
OBJ_BUCH-1848-001.book Page 13 Monday, May 13, 2013 10:57 AM