Refrigerant Lines | 17SM Split AH/AV Air Handler
8733826256 (2020/06)SM Split AH/AV Air Handler
Subject to change without prior notice
Refrigerant Charge, Line Sizing, and Capacity Multiplier Chart
Table 8 Refrigerant Charge, Line Sizing, and Capacity Multiplier Chart
Liquid Line Charge per Linear Foot
Table 9 Liquid Line Charge per Linear Foot
System
Models
Factory
R410A
Charge
(Oz)*
Refrigerant Line O.D. Size (Based on Equivalent Line Length)
Suction
Line
Riser
Max.
25 FT. 36 FT. 45 FT. 50 FT. 75 FT.
LIQ. SUC. LIQ. SUC. LIQ. SUC. LIQ. SUC. LIQ. SUC.
SM024
80 3/8 3/4 3/8 3/4 3/8 3/4 3/8 3/4 3/8 7/8 3/4
SM036
86 3/8 3/4 3/8 3/4 3/8 3/4 3/8 7/8 3/8 7/8 3/4
SM048
88 3/8 7/8 3/8 7/8 3/8 7/8 3/8 7/8 3/8 7/8 7/8
SM060
115 3/8 1–1/8 3/8 1–1/8 3/8 1–1/8 3/8 1–1/8 3/8 1–1/8 7/8
CAPACITY MULTIPLIER 1.00 0.995 0.990 0.990 0.980
EXAMPLE 1:
Model SM036 with 45 ft. of equivalent length of 3/8” O.D.
Liquid Line.
Total System Charge= Factory Charge + (45 ft. - 25 ft.) x .60
oz./ft.
Total System Charge = 93 oz. + (20 ft. x .60 oz./ft.) = 105 oz.
Additional 12 oz. of R410A refrigerant required.
EXAMPLE 2:
Model SM060 with 10 ft. of equivalent length of 3/8” O.D.
Liquid Line.
Total system charge= Factory charge + (25 ft. -10 ft.) x .60 oz./ft.
Total System Charge = 150 oz. + (15 ft. x .60 oz./ft.) = 141 oz.
Additional 12 oz. of R410A refrigerant required.
LIQUID LINE
SIZE, O.D.
1/4 5/16 3/8 1/2 5/8
R410A OZ
PER FOOT
.25 .44 .60 1.15 1.95