REPAIR INSTRUCTIONS
r120085e
-15/1
04.99
TUMBLE DRYER
Vented WTA34.. / WTA35..
I. SAFETY INFORMATION Page 1
II. OPERATION Page 1
III. DESCRIPTION OF FUNCTION / TECHNICAL INFORMATION Page 2
IV. CONSUMPTION RATES / ENERGY REQUIREMENT / OTHER DATA Page 6
V. REPAIRS Page 7
VI. SUPPLEMENTS Page 13
I. SAFETY INFORMATION
Before commencing repairs, ALWAYS disconnect the appliance from the power supply!
If tests have to be performed while the appliance is live, ALWAYS use a residual-
current-operated circuit-breaker! When repairs are complete, perform a function test, as
well as a safety test in accordance with VDE 0701.
1. Safety test in accordance with VDE 0701
• Plug in the tester mains plug.
In the case of switchover models connect L1 and L2 on the tester.
• Switch on the appliance (door must be closed).
• Perform the test.
II. OPERATION
1. Selecting the programme
• “Cottons/coloureds” Turn the programme selector in a clockwise direction to the
desired drying setting (6 automatic drying settings).
• Easy-care Turn
the programme selector in an anti-clockwise direction to the
desired setting (5 automatic drying settings).
• Timed programme Turn programme selector / time switch to the desired time.
2. Buttons
• ON/OFF Switches the appliance on / off.
• “Low heat” For delicate textiles. The temperature is reduced.