Installation and connection en
17
Total pressure loss values
Installation option
Notes
■ Route the exhaust air duct in such a
way that the dryer cannot draw the
moist, warm exhaust air back again.
■ The outlet for the exhaust air must
be designed or positioned in such a
way as to prevent any additional
backpressure (e.g. from a direct
ingress of wind) in the escaping
exhaust air, e.g. by using 90°, facing
down ~ Page 18
■ The outlet for the exhaust air duct
must be no more than 2.5 m higher
than the exhaust air opening on the
appliance.
Installation options for the exhaust air
duct:
■ Through a wall box into the open
air
Example: pipe connection - inside
diameter = 100 mm, smooth
■ Directly into the open air
Route the exhaust air duct directly
into the open air via an exhaust air
pipe through an open window.
Example: pipe connection - inside
diameter = 100 mm, flexible pipe,
corrugated
Total pressure loss Pipe connection
0 - 50 100
0 - 80 110
120
130
A = straight piece (1.0 m) 4
B = curved pipe (R = 200 mm) 4
C = straight piece (1.5 m) 6
D = pipe elbow 19
E = telescopic wall box with grid 14
Total pressure loss 47
A = curved pipe (R = 300 mm) 7
B = straight piece (1.5 m) 18
C = curved pipe (R = 100 mm) 10
D = straight piece (0.5 m) 6
Total pressure loss 41