Do you have a question about the BRANNSTROM CleanTrack 1000 B and is the answer not in the manual?
Brand | BRANNSTROM |
---|---|
Model | CleanTrack 1000 B |
Category | Measuring Instruments |
Language | English |
Guidance on replacing and repairing critical components.
Information provided by Brannstrom Sweden AB and manual usage.
Highlights new features in software version 2.20x.
Details changes made in the manual compared to previous versions.
Overview of the CleanTrack 1000 B system and its purpose.
Explanation of the system's purpose and its primary components.
Details the light transmission and scattering principle used for measurement.
Lists the components included in the CleanTrack 1000B system.
Specifies components that are always part of the Analyzing unit.
Lists electrical interfaces and signal setups within the system.
Mechanical and electrical installation details for the computer unit.
Details for mounting the computer unit.
Electrical connection and power requirements for the computer unit.
Mechanical and electrical installation for the converting unit.
Mounting guidelines for the converting unit.
Electrical connections and power supply for the converting unit.
Details on installing the analyzing unit.
Provides general arrangement drawings for the analyzing unit.
Mechanical mounting instructions for the analyzing unit.
Electrical connection details for the analyzing unit.
Installation requirements for sample inlet probes and outlet stubs.
Guidelines for sample inlet and outlet piping.
Installation details for optional fresh water piping.
Details on piping for the air motor option.
Information on flow meter and speed log requirements.
General requirements and selection criteria for flow meters.
Details on the standard flow transmitter used by Brannstrom.
General requirements for the speed indication system.
Details regarding the optional paper printer module.
Explains how to calculate system response times and provides examples.
A step-by-step checklist for initial system startup.
Guidance on setting pressure alarm limits to protect the sample pump.
Instructions for handling and replacing Zener barriers.
Procedures for installing and replacing the measuring cell.
Step-by-step guide for replacing the measuring cell.
Guidance on demonstrating intrinsically safety margins for the installation.
Key safety and preparation points before starting the system.
Detailed steps for starting up the sample pump and system.
Steps for safely shutting down the system.
Procedures for extended shutdown or protection against freezing.
Overview of the main menu and status indicators.
How to change numerical settings using the interface.
Explanation of the function of various keys on the interface.
Information on accessing functions using passwords.
Details on the indicators and keys on the Measuring Cell front.
Overview of the main menu options and their functions.
Description of the default screen shown after inactivity.
Details on operating the system and its various modes.
Information displayed and settings for the 'RUNNING' mode.
Configuration options before starting a discharge.
Selection of the discharge line for operation.
Selection of oil type, including bio-fuel blends.
Allows insertion of manual values during equipment malfunction.
Displays system status for immediate discharge readiness.
Lists and explains system alarms and their status.
Information on how recorded data is stored and managed.
Examples of recorded data lines and their meanings.
Information on using USB memory sticks for data transfer.
Details on attaching and recognizing a USB memory stick.
Procedure for saving printouts to a USB stick.
Describes functional tests to verify system operation.
Procedures for checking and calibrating the measuring cell.
Indicates the zero calibration status of the connected measuring cell.
Prepares the system for zero calibration using manual or auto flush.
Initiates the zero calibration process for the measuring cell.
Instructions on how to replace the measuring cell.
Allows configuration of various system parameters.
Configuration of discharge lines and overboard valve control.
Setup for Zener barrier flow input 1.
Setup for Zener barrier flow input 2.
Setup for CVF flow input.
Configuration of pressure settings and alarms.
Explains pressure alarm functions for sample and water.
Settings for optional motor features on the converting unit.
Configuration of speed input sources and limits.
Standard system configuration settings.
Configuration of alarms and extra system features.
Details about the computer unit's functions.
Instructions for using USB memory sticks.
Setting the system's real-time clock.
Configuration of static or DHCP IP addresses.
Procedure for calibrating the touch screen display.
Procedures for checking system communication and components.
Overview of printed circuit boards in the system.
Enables manual activation of relay outputs for testing.
Displays transmitted NMEA sentences from the GPS.
Details about the optional paper printer module.
Information on the trial period and its activation/deactivation.
Details on the computer unit's power supply.
Information on the Computer unit's Input/Output PCB.
Information on the Converting unit's Standard I/O PCB.
Information on the optional Extended Converting unit I/O PCB.
Information on the Converting unit's Zener Barrier PCB.
Displays readings from the measuring cell.
Details on optional Modbus RTU communication.
Displays the approvals granted to the CleanTrack 1000B unit.
Troubleshooting steps for computer or converting unit malfunctions.
A comprehensive list of system alarms and their descriptions.
Troubleshooting for errors related to system files.
Troubleshooting for communication errors between system components.
Alarms related to external sensors like GPS and flow meters.
Alarms triggered by measurement results exceeding limits.
Alarms related to sample pressure and water conditions.
Troubleshooting for issues with the optional paper printer.
Optional motor alarms for the extended converting unit.
Alarms related to sample pump feedback and valve status.
Visual indicators on the various PCBs of the system.
LED indicators on the Computer unit I/O PCB.
LED indicators on the Converting unit I/O PCB.
LED indicators for the optional Extended Converting unit I/O PCB.
LED indicators on the Zener barrier PCB.
Procedure for upgrading the system software via USB.
Instructions for replacing the computer unit's internal battery.
How to save recorded data and settings to a USB stick.
Regular checks and servicing schedule for the system.
Details on accuracy verification and restricted access to the measuring cell.
Instructions for cleaning the sample pump's inlet filter.
Procedure for refilling oil in the sample pump shaft seal.
Lists of spare parts for different system units.
List of spare parts for the computer unit.
List of spare parts for the converting unit.
List of spare parts for the analyzing unit.
List of spare parts for various sample pump models.
List of fuses for the power supply unit and converting units.
Recommendations for essential spare parts to keep on hand.
Details on consumable items like batteries and printer rolls.
Guidelines for storing the unit before installation.
Drawings related to the computer unit's mounting.
Drawings showing the dimensions of the converting unit.
Diagrams for various analyzing unit configurations.
Arrangement drawing for skid-mounted Ex. motor sample pump.
Drawings for analyzing unit with an external sample pump.
Diagrams for analyzing unit with freestanding external pump items.
Arrangement drawings for analyzing unit with air motor sample pump.
Dimensional drawings of the SPP-100 sample pump with Ex. motor.
Drawings for Nikuni sample pump mounted on a bulkhead.
Drawings for Matre sample pump mounted on a bulkhead.
Drawings for the system connection box.
Diagrams related to the measuring cell replacement procedure.
General arrangement (GA) plans for system configurations.
Identifies parts in a typical system arrangement drawing.
GA plan for skid-mounted Ex. motor sample pump system.
GA plan for bulkhead penetrating sample pump systems.
GA plan for systems with an air motor sample pump.
GA plan for systems with a pilot-controlled air motor sample pump.
Electrical cable diagrams for system components.
Cable diagram for electrical Ex. motor sample pump.
Cable diagram for bulkhead mounted sample pump.
Cable diagram for air motor sample pump.
Internal wiring diagram for electrical sample pump motor.
Internal wiring for optional extended SPP-100 sample pump motor.
Installation arrangements for sample probes.
Arrangements for 1-inch sample probes.
Diagrams for the CleanTrack flow meter unit.
EC Type Examination Certificate (MED-D).
DNV Type Approval certificate for the system.
German Type Approval certificate for the system.
China Classification Society (CCS) IMO Certificate.
China Classification Society (CCS) Type Approval.
Nippon Kaiji Kyokai (NK) Type Approval.
Russian Maritime Register of Shipping (RMRS) Type Approval.
EU Declaration of Conformity for the equipment.
EC Type Examination Certificate for the Zener Barrier PCB.
EC Type Examination Certificate for the Measuring Cell.
Technical brochure for Danfoss pressure transmitters.
Manufacturer's Declaration of Conformity for Siemens pressure transmitters.
Siemens EU Declaration of Conformity for pressure transmitters.
EC Type Examination Certificate for Siemens ATEX pressure transmitters.
EU-Type-Examination Certificate for Siemens flow meters.
EC-Type Examination Certificate for Fuji electronic pressure transmitters.
Instructions for Elprom explosion proof motors.
Detailed instructions for Elprom motors.
EC Type Examination Certificate for Elprom motors.
EC Type Examination Certificate for Elprom motors.
Certificate for Hummel cable glands.
Information on obtaining ATEX certificates for Speck pumps.
Contains detailed workshop test procedures.
Includes a calibration certificate for the equipment.