5704 - 12
BINC Rev: 11/97 Service Documentation
Service Information
BAG Rev: 8/97 5704
Possible Malfunctions
Malfunction Possible Cause Action
Bad shaving quality. - Resonating shaving foil - Exchange shaving foil frame.
frame.
- Jammed cutting heads. - Exchange cutting heads.
- Loose foils. - Exchange shaving foil frame.
- Medium trimmer does - Exchange shaving foil frame
not work. probably exchange cutting
heads.
- False operation - Explain how to operate the
(shaver position). shaver.
Skin irritation. - Deformed or damaged foils. - Exchange shaving foil frame.
- Medium trimmer snapped out. - Exchange shaving foil frame.
- Broken welding spot medium - Exchange shaving foil frame.
trimmer
- Jammed medium trimmer. - Exchange shaving foil frame.
- Jammed cutting heads. - Exchange cutting heads.
- Broken blades. - Exchange cutting heads.
Damaged foil. - Mechanically damaged, fall. - Exchange shaving foil frame.
- Deformed when attached or - Exchange shaving foil frame.
removed.
Shaver too noisy. - Resonating shaving foil frame. - Exchange shaving foil frame.
- Resonating medium trimmer. - Exchange shaving foil frame.
- Swivel frame has end play. - Exchange head carrier,
swivel frame and shaving foil
frame.
- Swivel frame has a radial play. - Exchange swivel frame and
shaving foil frame.
- Sliding seal is (partially) - Exchange sliding seal.
snapped out.
- Resonating unlocking plate. - Exchange swivel frame.
- Bearing screw is loose - Replace and tighten screw;
or missing exchange head carrier, if
necessary.
Shaving foil frame - Jammed notches or unlocking - Exchange swivel frame and
does not snap in. plate. shaving foil frame.
Shaving foil frame - See above. - See above.
does not snap out. - Unlocking button has not - Instruct customer.
been pushed.