TRIAD SERIES 3-PIECE BALL VALVE
Installation, Operation, and Maintenance Manual
 of ©  BRAY INTERNATIONAL INC ALL RIGHTS RESERVED BRAYCOM The Information
contained herein shall not be copied transferred conveyed or displayed in any manner that would
violate its proprietary nature without the express written permission of Bray International Inc
Inspection as a minimum shall include reviewing the following
Packaging
Flange covers
Dryness
Cleanliness
These are general guidelines for valve storage Please consult the
factory for information regarding specific requirements
CAUTION
Do not stack the products on top of each other
 General Storage Requirements
Manually actuated valves may be stored in the vertical or
horizontal position For air or hydraulically actuated valves
the preferred orientation is with the valve stem in the vertical
position Access ports should be secured to prevent unauthorized
entry and prevent contamination
The preferred storage location is a closed clean and dry
environment Do not expose the product to temperature
extremes
NOTICE
The preferred temperature range is F (C) to F (C)
For long-term storage in temperatures lower or higher than
the preferred range please consult the factory for information
regarding specific requirements
End protectors shall remain on the valve ends to prevent the
entrance of dirt debris or insectswildlife
Product shall remain in the original shipping container with the
original packaging materials
Valves and equipment containing elastomers including O-rings
must be stored in a climate-controlled warehouse according to
SAE-ARPD requiring
 The ambient relative humidity to be less than 
 No exposure from direct ultraviolet or sunlight
 Protection from ozone generating equipment or combustible
gases and vapors
 Storage at temperatures below F (C) away from
direct sources of heat
 No exposure to ionizing radiation