Actuator Mounting
Inspect the valve actuator mounting surface stem mounting
hardware bracket couplingadapter and actuator package
for damage wear or any other irregularity which could aect
the operation and performance of the valve or actuator
package
Follow specific actuator installation operating and
maintenance instructions
Valve stem shall be in the upright position
Ensure valve is properly supported when mounting the
actuator
Valve closure position
a If the actuator is a spring return fail to close or double
acting style actuator the valve closure shall be set to
closed position
b If the actuator is a spring return fail to open style
actuator the valve closure shall be set to open position
Attach the mounting bracket to the valve with provided
hardware hand tight A lifting device may be required based
on the size and weight of the bracket
Install the couplingadapter on the valve stem A lifting
device may be required based on the size and weight of the
couplingadapter
Proper valve and actuator performance requires alignment
between the valve stem and actuator drive Misalignment can
cause premature wear of the valve and actuator components
Ensure actuator drive orientation is in the proper position
Lift the actuator package from its storage location and lower
the actuator so the actuator drive is in a direct line with the
valve stem Support actuator package once actuator is on the
mounting bracket Be careful not to force the valve stem into
the valve as the actuator drive and stem are in contact
Tighten the actuator provided mounting hardware hand tight
Maintain the actuator package support
Cycle actuator to times to allow the assembly to center
the valve stem couplingadapter and actuator drive
Tighten the mounting hardware at the valve and actuator
The actuator travel stops shall be adjusted to ensure proper
valve closure position open and closed The actuator stops
shall be set every time the actuator is removed from the
valve