EasyManua.ls Logo

Bray Flow-Tek Triad Series - Troubleshooting

Default Icon
35 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TRIAD SERIES 3-PIECE BALL VALVE
Installation, Operation, and Maintenance Manual
 of ©  BRAY INTERNATIONAL INC ALL RIGHTS RESERVED BRAYCOM The Information
contained herein shall not be copied transferred conveyed or displayed in any manner that would
violate its proprietary nature without the express written permission of Bray International Inc
NOTES
Bray does not accept any responsibility for the product if wear parts not tested and approved by Bray are used
Bray does not accept any responsibility for the product if maintenance instructions are not followed during maintenance
 TROUBLESHOOTING
TROUBLE POSSIBLE CAUSE SOLUTION
Packing Leakage Packing Consolidation
Packing Wear
Improper Repair
Tighten gland bolting or lock nut
to eliminate leak If leak continuous
follow proper maintenance and
repair
Seat Leakage Seat Wear
Media Damage
Improper Repair
Follow proper maintenance and
repair
Body Seal Leakage Improper installation or welding technique
Improper Repair
Tighten body bolts per Table 
following tightening technique
outline in valve assembly section
If leak continues follow proper
maintenance and repair