EasyManuals Logo

Breas Vivo 45 LS Quick Reference Guide

Breas Vivo 45 LS
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Vivo 45 LS
Quick Reference Guide for Healthcare Professionals
Rear View
Equipment Designation
Exhalation valve port
Connection for low
pressure/bleed-in
oxygen
Item/ Symbol Description Color
CO
2
interface port
SpO
2
interface port
Remote start/stop and audio pause
port
Remote alarm, nurse call interface port
Mains/ External DC inlet
This is not a complete guide for the Vivo 45 LS. See your manual for complete instructions.
Setting Up and Powering on the Ventilator
All users must be trained in the use of the Vivo 45 LS prior to operating
the device.
Before operating the ventilator, inspect the ventilator, power supply,
power cord and accessories for any signs of damage. Do not use the
device or accessories if damage is suspected.
Do not use the ventilator while positioned in a warm place, such as in
direct sunlight or close to a radiator as this may lead to a temperature
outside of specications.
Placing the Ventilator Before Use
Place the Vivo 45 LS on a solid at surface. It should be placed lower than
the patient. Make sure that nothing can block the patient air inlet. Make
sure that nothing can block the cooling air inlet or outlet.
Connecting the Vivo 45 LS to Mains (AC Power Outlet)
1. Plug the power supply into the power
inlet.
2. Make sure a clicking sound is heard to
ensure the power supply is completely
inserted.
3. Connect the power supply’s power cord to
the mains supply.
Connecting Accessories
Connecting and Disconnecting the
Accessory Cables
1. Insert the cable in the appropriate port.
(See Rear View)
2. Make sure to insert the connector with
the marking pointing upwards.
3. Pull the connector sleeve, not the cable itself or the cable strain relief to
release the connector.
EtCO
2
sensor
SpO
2
Connection
interface
SpO2 nger clip sensor Click-in battery
1
Click-in Battery
The click-in battery is intended as a power source during transportation, or
if the primary AC power source fails.
Installing the Click-in Battery
1. Lift Handle and press button 1 to release
the side cover.
2. Open and remove the side panel.
3. Insert the click-in battery. Make sure
the latch at the bottom of the click-in
compartment is engaged.
4. Close the side panel. Make sure there is a
clicking sound to secure the side panel.
When removing the battery, press down
the latch at the bottom of the battery
compartment and tilt the ventilator
sideways.
1
PtcCO
2
sensor
Customer Support Line: 855-436-8724
Monday through Friday 8am to 5pm EST
009018
Revision D-1

Other manuals for Breas Vivo 45 LS