Loading...
8.8
Fuses
The
machine
is
protected
by
three
fuses
mo.
Disconnect
the
mains
cable
before
removing
untad
on
the
PSU
front
panel.
I
a
fuse
holder.
Replacement
Values:
fflain
fuse
2.5
A
(240V.)
or
5
A
(110V.)
20
mm
anti
surge
Deck
power
2.5
A
(240V.)
or
5
A
(110V.)
20
mm
anti
surge
Electronics
40V.
rail
5
A
semi
delay
20
mm
anti
surge
protection
8.9
Record
or
Replay
failure
of
an
individual
channel
Each
individual
channel
module
carries
the
all
the
record
(with
the
exclusion
of
the
master
bias/erase
oscillator)
electronics
and
all
the
replay
electro
If
a
single
channel
fails
an
unused
channel
can
be
substituted.
To
remove
a
channel:
Undo
the
two
screws
(one
top
and
one
bottom)
on
the
channel
module,
insert
a
screwdriver
under
the
top
edge
of
the
module
and
gently
ease
it
out
-
the
first
half
inch
or
so
of
movement
will
be
stiff
until
the
edge
connectors
is
released.
To
replace
a
channel
:
Engage
the
top
and
bottom
in
the
guides
and
gently
slide
it
home
into
the
screws.
Channel
alignment
should
be
checked
as
edges
of
the
channel
module
connector.
Replace
the
two
per
Appendices
A,B,C.
MECHANICAL
FAULT
FINDING
:
1.
Lack
of
capstan
drive,
all
other
functions
O.K.
-
check
that
the
two
drive
belts
are
intact.
2.
Excessive
wow
and
flutter
-
one
drive
belt
broken.
3.
Slipage
or
running
slow
pinch
roller
pressure
too
low
or
broken
drive
belt.
a
Rnlav
Failure
All
deck
relays
430-600
ohm
4
pole
change-over.
Channel
record-on
rel^Miniature,
low
profile
24V.
O.C.
2
pole
change-over.
Line,
sync,
replay
relay
-
ITT
(HZ)
Available
only
through
Brenell
or
IT
.
All
other
mechanical
problems
should
be
referred
to
the
Brenell
factory
or
to
an
appointed
Agent.
For
belt
change
procedure
see
appendix
D