Battery operated photoelectric smoke detector RM L 3100 with mute function
IMPORTANT:
Read these operating instructions and store them in a safe place.
Heed and follow the safety instructions.
Introduction
These operating instructions must be read carefully and completely. They are an integral part of your newly-purchased, battery-operated
photoelectric smoke detector and contains important instructions for the operation and handling of the device.
In the following the device will only be referred to as a smoke detector. When using this product, all safety instructions must be followed at
all times. If you have any questions concerning the use of the smoke detector, contact your dealer or service company. These operating
instructions must be kept and if necessary transferred with the item to any third party purchasing it. Furthermore, you must make sure the
smoke detector remains in good operating condition.
Technical specifications
Device: RM L 3100
VDS approval: DIN EN 14604/VDS +
Q label/G216044
Range of application: according to DIN 14676 Audible alarm: 85dB (at a distance of
3 m)
Power supply: integrated 3V DC lithium battery
Battery life: 10 years
Ambient temperature: 0 ºC to 39 ºC Protection class: IP 20
Choosing the installation site
Installation sites for smoke detectors are regulated in the binding application standard DIN EN 14676, which is applicable in Germany.
1. To provide comprehensive protection smoke detectors should be installed in all rooms, corridors, storage areas and basements . It may
be necessary to install more than one smoke detector per area, especially in corridors longer than 15 m. We recommend using several
smoke detectors for rooms larger than 60 m
2
and corridors longer than 10 m.
2. You should at least provide minimum protection and install a smoke detector in every bedroom and children's room, as well as in
corridors used as emergency routes.
3. For optimal protection there should be at leastone smoke detector installed in every room and corridor.
4. Because smoke rises, smoke detectors must always be installed on the ceiling, preferably in the centre of the room, in a horizontal
position. According to DIN EN 14676, a distance of at least 0.5 m from all furniture and the ceiling and walls must be observed.
5. Do not install under the ridge of a roof (place at least 30 - 50 cm below the ridge), near air ducts, or in areas with a severe draught.
Installation sites to be avoided
1. Do not install smoke detectors in areas subject to draught, such as near air conditioner or ventilation intakes.
2. Bathrooms, showers, and rooms where the temperature exceeds 39 ºC or falls below 0 ºC.
3. Under the ridge of a roof, since smoke-free aircan accumulate there in the event of a fire.
4. Kitchens, garages, laundry or boiler rooms, where cooking fumes, vehicle exhaust, dust and humidity may trigger a false alarm.
5. Very dusty or dirty areas. Dirt and dust may accumulate in the smoke alarm and hinder its reliability during operation.
6. Less than 1.50 m from a fluorescent lamp.
bedroom
bathroom
kitchen
corridor
children's
ro
om
children's
room
living room
Smoke detector installation and start-up The mounting parts included are designed for concrete ceilings. If you have a different mounting
surface you will need to purchase appropriate mounting parts at a specialist store.
1. Mark the position of the smoke detector on the ceiling.

Other manuals for brennenstuhl RM L 3100

Questions and Answers

  • J
    jennifer72Aug 6, 2025
    What to do if my brennenstuhl RM L 3100 Smoke Alarm keeps beeping every 40 seconds?
    • S
      Sharon Jones DDSAug 6, 2025
      If your brennenstuhl Smoke Alarm beeps every 40 seconds due to an error, you can temporarily deactivate this message for 10 hours by pressing the test button. However, the device must be replaced immediately.
  • E
    Emily OlsonAug 10, 2025
    Why does my brennenstuhl RM L 3100 Smoke Alarm LED flash every 40 seconds and beep?
    • S
      smithnathanielAug 11, 2025
      If your brennenstuhl Smoke Alarm's LED flashes once every 40 seconds, accompanied by beeping, it indicates that the integrated battery is weakening. You can temporarily stop the beeping for 10 hours by pressing the test button. However, the smoke alarm must be replaced immediately.
  • B
    Barbara RogersAug 15, 2025
    Why is my brennenstuhl Smoke Alarm beeping and the LED flashing every 10 seconds?
    • J
      Javier SanchezAug 15, 2025
      If the LED on your brennenstuhl Smoke Alarm flashes once every 10 seconds and beeps, this indicates that the product has reached the end of its lifespan and the device must be replaced immediately.
  • T
    Timothy MasseyAug 19, 2025
    What to do if my brennenstuhl RM L 3100 Smoke Alarm has a continuous, pulsating tone?
    • B
      Bryan AndersonAug 19, 2025
      If your brennenstuhl Smoke Alarm emits a continuous, pulsating tone and the LED flashes once per second, you should leave the danger zone immediately. If you were testing the device, release the test button.
  • K
    Kyle BarrettAug 25, 2025
    How to stop brennenstuhl RM L 3100 Smoke Alarm from beeping three times?
    • A
      Ashley RussellAug 25, 2025
      Releasing the test button will stop the brennenstuhl Smoke Alarm from beeping three times every 1.5 seconds.
  • T
    Tammy WarrenAug 28, 2025
    What does it mean when the LED flashes once every 40 seconds on brennenstuhl RM L 3100 Smoke Alarm?
    • E
      Evan RamosAug 28, 2025
      When the LED flashes once every 40 seconds on your brennenstuhl Smoke Alarm, it indicates that the smoke detector is working properly.
  • S
    stephanie34Sep 1, 2025
    Why is the LED on my brennenstuhl RM L 3100 Smoke Alarm flashing once every 8 seconds?
    • D
      dawnstarkSep 1, 2025
      The brennenstuhl Smoke Alarm is de-sensitised for approximately 10 minutes when the LED flashes once every 8 seconds.

brennenstuhl RM L 3100 Specifications

General IconGeneral
TypeOptical smoke alarm
Power Supply9V battery
Test ButtonYes
LED IndicatorYes
Operating Temperature0°C to +40°C
Standby Current10 µA
Alarm Volume85 dB at 3 meters