12. pour plenty of cold water onto the evaporator and direct the sediment removed into the basin
beneath with the aid of the brush.
During cleaning of the evaporator, take care:
• not to bend coils
• not to detach the water supply pipes
• not to remove the evaporator thermostat
13. remove (Fig. 6) and clean with ordinary washing-up liquid:
• overflow pipe (Fig. 2)
• ice-cube chute (2)
• sprayer bank (3), taking care to remove side caps (4)
• sprayer bank feed pipes (5)
14. clean with the same washing-up liquid, removing any sediment with a non-abrasive sponge:
• evaporator cover panel
• basin
• tilting panel (7 in Fig. 6)
15. rinse and refit (Fig. 6):
• sprayer bank feed pipes (5)
• sprayer bank (3), after repositioning side caps (4)
• overflow pipe (Fig. 2)
• ice-cube chute (2)
• evaporator cover panel (Fig. 4)
16. prepare to perform the sanitizing operations described in the next chapter
3 SANITIZING
Use a 200 mg/l solution of sodium hypochlorite and water (or a solution of ½ ounce of normal
bleach to 1 gallon of water), or one of the solutions commonly used to disinfect babies' feeding
bottles; in this case, check that the sanitizing product is:
• authorized by your country's Ministry of Health
• suitable for use with food-making machinery
• not harmful to the materials and components of this appliance
For the directions for use and concentrations, please refer to those shown on the packaging and
recommended by the manufacturer. We recommend using the solution at the temperature of 25°C.
1. fill basin with sanitizing solution. Refer to the table for the amount of solution required,
depending on daily output (Fig. 2)
2. reposition front panel
‼
Before connecting the appliance to the mains power supply, ensure that all cables and
electrical wiring are perfectly dry.
3. connect appliance to mains power supply and switch on with luminous switch
4. operate appliance for at least 20 minutes
5. switch off appliance and disconnect from mains power supply
6. remove front panel (Fig. 1), top, and evaporator cover panel (Fig. 4)
7. remove (Fig. 6) and immerse in sanitizing solution for 30 minutes:
• overflow pipe (Fig. 2)
• ice-cube chute (2)
• sprayer bank (3) and side caps (4), after removing them from the bank
• sprayer bank feed pipes (5)
• evaporator cover panel (Fig. 4)
8. pour sanitizing solution onto both sides of the evaporator (Fig. 5) and tilting panel (7 in Fig. 6)
and distribute with a stiff brush and a brush with soft bristles
9. thoroughly rinse evaporator, tilting panel and inner basin by pouring plenty of cold water over
them