Troubleshooting
Issue Reason Solution
No Water Flow Water not connected
Water valve has malfunctioned
Outlet is blocked
Water pressure in excess of
70PSI (5 bar)
Check water connection
Replace valve
Unblock or replace part
Fit water regulator to mains supply
Unit will not
shut-o
Unit has lock on feature in use
Water valve has malfunctioned
Push the operating button to deactivate
Replace the water valve
No chemical
suction
Low water pressure
Tube kink
Chemical container empty
Blocked foot valve
Blocked dilution valve
Loose dilution valve (open
atmosphere)
Flood ring in outlet has moved
Minimum 30PSI running water (2 bar)
Re-route tube
Replenish chemical
Clean or replace valve
Remove and clean part
Check dilution clamp
Replace outlet tube assembly
Too much
chemical
Dilution pin on wrong setting
Chemical is stiening
Change ratio
Lower chemical below unit injection point