CYLINDER SPECIFICATIONS:
When purchasing or exchanging a cylinder for your gas stove, it must be constructed and marked in
accordance with the specifications for LP gas cylinders of the U.S. Department of Transportation
(DOT) or the National Standard of Canada, CAN/CSA-B339 as applicable with a listed over-filling
prevention device (OPD).
3
WARNING
WARNING
LP GAS CYLINDER (NOT SUPPLIED WITH THIS STOVE)
The LP (Liquid Propane) gas cylinder specifically designed to be used with this stove must have
a 20 lb. (9.1 kg) capacity incorporating a Type 1 cylinder valve and an over-filling protection
device (OPD).
• DO NOT connect this stove to an existing #510 POL cylinder valve with Left Hand threads. The
Type 1 valve can be identified with the large external threads on the valve outlet.
• DO NOT connect to a propane cylinder exceeding this capacity.
• DO NOT connect to a cylinder that uses any other type of valve connection device.
• FOR OUTDOOR USE ONLY. DO NOT operate indoors or in an enclosed area such as a tent,
screened porch, garage, shed or breezeway.
• Use your stove OUTDOORS in a well ventilated space away from buildings, trees, fences or
other combustible materials or structures to prevent dangers associated with gas accumulation
and toxic vapors. We recommend your stove be situated at least 10 feet (3 meters) from
buildings.
• DO NOT use on wooden decks or surfaces that could burn.
• Maintain a minimum clearance of 36 inches (90 cm) between all sides of stove and walls or
other combustible material. Do not locate this appliance under overhead unprotected
combustible surfaces.
• DO NOT install in or on a recreational vehicle and/or boat.
• DO NOT use on apartment complex patios or balconies.
INSTALLATION INFORMATION:
The installation of this appliance must be in accordance with:
All applicable local codes, or in the absence of local codes, either:
• National Fuel Gas Code,
• ANSI Z223.1 1988 or latest edition (USA)
• Natural Gas Installation Code: CAN/CGA B149.1 (Canada)
• Propane Installation Code: CAN/CGA B149.2 (Canada)
To check your local codes, see your local LP gas dealer or natural gas company.
This stove shall not be connected to a natural gas supply line.