EasyManua.ls Logo

Brita Mypure - Troubleshooting; Troubleshooting Common Issues

Brita Mypure
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH 9
Troubleshooting
A No water flow
Cause: Water intake closed.
Troubleshooting: Open the water intake at the upstream shut-off
valve or by closing the locking handle (3) on the
filter head (5).
B No or low water flow in spite of open water intake
Cause: Mains pressure too low.
Troubleshooting: Check mains pressure. If the fault continues,
check the tap and filter cartridge and replace if
necessary.
Cause: Filter head not mounted in direction of water
ow.
Troubleshooting: Dismantle filter head and install in direction of
water flow (see step 4, chapter 2).
C Leak
Cause: Screwed connections not fitted correctly.
Troubleshooting: Check mains pressure. Check all screwed
connections in accordance with (see step 4,
chapter 2).
D No LED indication by usage
Cause: Battery is not inserted in a correct way or is
used up.
Troubleshooting: Check if battery is inserted properly. If neces-
sary, replace the battery.
Check also that plastic tab has been removed.
IV. Maintenance & Cleaning V. Troubleshooting