10 ENGLISH
7 Technical Data of the A 1000 cartridge
Operating pressure 2 bar to max. 8.6 bar
Water intake temperature 4°C to 30°C
Ambient tempera-
ture during
operation 4°C to 40°C
storage/transport –20°C to 50°C
Nominal service flow
(acc. to DIN 18879)
60 L/h
Working flow range and associated
pressure loss
30–180 L/h / 0.2–1.4 bar
Bed Volume 0.23 L
Weight (dry/wet) 0.4 kg/0.9 kg
Rated filter capacity 10,000 L
Chlorine reduction NSF 42 Class I (50%)
Particle retention NSF 42 Class I (0.5 µm)
Chlorine reduction DIN EN 14898 Class 1 (>90%)
Dimensions
(Width/Depth/
Height)
Filter system
(filter head with
filter cartridge)
106 mm/92 mm/232 mm
Filter cartridge 86 mm/86 mm/224 mm
Installed dimen-
sions (vertical
installation with
wall mounting)
137 mm/122 mm/232 mm
Operating position Horizontal and vertical
Water inlet connection G3/8"
Water outlet connection G3/8"
8 Troubleshooting
A No water flow
Cause: Water intake closed.
Troubleshooting: Open the water intake at the upstream shut-off
valve or by closing the locking handle (2) on the
filter head (1). Check hoses for kinks.
B No or low water flow in spite of open water intake
Cause: Mains pressure too low.
Troubleshooting: Check mains pressure. If the fault continues,
check the filter system and filter cartridge and
replace if necessary. Check hoses for kinks.
Cause: Filter head not mounted in direction of water
ow.
Troubleshooting: Dismantle filter head and install in direction of
water flow (chapter 3.2).
C Leak
Cause: Screwed connections not fitted correctly.
Troubleshooting: Check mains pressure. Check all screwed
connections in accordance with chapter 3.2.
D Incorrect display or incorrect settings on the electronic
cartridge exchange indicator with display
Cause: Buttons pressed in wrong order or wrong
buttons pressed.
Troubleshooting: Press and hold the RESET button for 8 seconds.
If you are still experiencing issues, please call BRITA Customer
Care – see back page for more details.