Ensure the pump is operating, and visually check the pads externally for even water
distribution to the pads.
Check if the ventilation within the targeted cooling area is sufficient.
Selecting the wrong, or insufficient ventilation points, could result in excessive air
movement causing draughts, or inadequate air distribution resulting in poor
performance.
Check the water supply to the unit is turned ON.
Ensure the water inlet is operating correctly.
Ensure the water system is operating to the minimum and maximum water levels.
Check the fan operates, and that air is discharging from the outlet diffusers.
Check the filter pads are not damaged, and/or the material hasn't deteriorated.
If fitted check if the Networker is not displaying an Error Code relating to the units
operation (refer to Brivis Service).
If humidity rises too high.
Check for sufficient ventilation. (i.e. make sure enough doors and windows are
open).
If outside humidity is increasing, operate the Cooler without the pump and with fan
only.
If the fan will not start.
The power supply isolation switch at the unit may not be turned ON.
The Wall Control may not be turned ON, or set at a comfort level that requires the
Coolers fan to operate.
The fan may be delayed due to the pre-programmed time to allow time to open the
ServoSeal (Contour models only), fill the Coolers tank with water, and Pre-Wet the
filter pads.
If fitted the Networker may be in Time Delay mode.
Check the 10 Amp fuse in the meter box
If the air smells a little different.
New Celdek pads can give off a mild odour while they are settling in. This is quite
normal, it will dissipate quickly as the new pad is constantly flushed during use.
Commonly Asked Questions, Answered:
1. Can you run evaporative cooling through the same duct work as my Central
Heating?
No, the differing technology between ducted heating and evaporative cooling don't allow the
units to share the same duct work.
2. How much water does an evaporative cooler use?
This is dependant upon the weather conditions, model (size), operation settings and type of
water quality system.
3. How many windows, doors should I have open?
Refer to Page 5 of this manual.
4. Why is moisture building up on my tiles or surfaced areas?
The air stream from the Cooler outlet/s is incorrectly directed to a cool surface. Maximum
Cooling efficiency will be achieved when the air flow is directed over the ceiling, or external
wall surface.

Other manuals for Brivis Contour Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brivis Contour Series and is the answer not in the manual?

Brivis Contour Series Specifications

General IconGeneral
BrandBrivis
ModelContour Series
CategoryFreezer
LanguageEnglish

Related product manuals