Seasonal Maintenance.
The start and end of season maintenance procedures as set out below, will ensure you
obtain the optimum performance and longevity.
Start of Season Maintenance.
Start of season maintenance and any repair work should be carried out by Brivis or an
experienced service technician.
Seasonal Maintenance.
The start and end of season maintenance procedures as set out below, will ensure you
obtain the optimum performance and longevity.
Start of Season Maintenance.
Start of season maintenance and any repair work should be carried out by Brivis or an
experienced service technician.
• Ensure the power supply isolating switch is in the OFF position.
• Check filter pad material for holes or deterioration. The pads will deteriorate over
time and lose their water absorption ability. Replace pads as required.
• Clean the tank and internal surfaces.
• Clean the filter pads and flush water.
• With the filter pads in position, switch ON the power supply isolating switch and
operate the unit.
• Ensure the pump is operating, and visually check the pads externally for even water
distribution.
• Ensure the water inlet is operating correctly.
• Ensure the water system is operating to the minimum and maximum water levels.
• Check that the water supply pressure is sufficient to fill the tank within the allotted
time.
• Check the fan operates, and varies speed between the minimum and maximum
setting on the Wall Control.
• On Contour models, ensure the ServoSeal mechanism is opening and closing
correctly.
End of Season Maintenance.
• Turn OFF the water supply to the unit at the isolating stop tap.
Note for Networker Models:
• Do not turn OFF the power supply to the Cooler for longer than is necessary for
carrying out maintenance.
• If the power supply is turned OFF for too long, the Networker will lose its Time/Day
settings.
• If power must be switched OFF, first make sure the ServoSeal (Contour models
only) is completely closed.
Checklist.
If the system is not cooling adequately.