MODEL QTRE100H
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by quali ed
personnel in accordance with all applicable codes and standards,
including re-rated construction codes and standards.
4. Suf cient air is needed for proper combustion and exhausting of
gases through the ue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturers
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
8. This unit must be grounded.
9. When applicable local regulations comprise more restrictive
installation and/or certi cation requirements, the aforementioned
requirements prevail on those of this document and the installer
agrees to conform to these at his own expenses.
10. When performing installation, servicing or cleaning this unit, it
is recommended to wear safety glasses and gloves.
CAUTION
!
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. This product is designed for installation in at ceilings only. DO
NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Please read speci cation label on product for further information
and requirements.
MODEL QTRE100H
HUMIDITY SENSING FAN
READ AND SAVE THESE INSTRUCTIONS
CLEANING & MAINTENANCE
Installer: Leave this manual with the homeowner.
For quiet and ef cient operation, long life, and attractive appearance
- lower or remove grille and vacuum interior of unit with the dusting
brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the motor with the exact service motor. The impeller should also
be replaced.
SENSOR CLEANING
The humidity sensor is mounted in the control housing. The sensor
will operate most reliably when cleaned occasionally as follows:
1. Disconnect power at service entrance.
2. Remove the grille. Use a dry dustcloth, clean toothbrush,
or lightly vacuum to clean sensor and grille. DO NOT USE
ABRASIVE CLOTH, STEEL WOOL PADS, OR SCOURING
POWDERS.
3. DO NOT USE cleaning sprays, solvents, or water on or near
the sensor!
OPERATION
The humidity control and fan can be operated separately. Use a
1- or 2-function wall control. Do not use a dimmer switch to operate
the humidity control. See “Connect Wiring” for details.
SENSOR OPERATION
The humidity-sensing
fan uses a sophisticated humidity sensor
that responds to: (a) rapid to moderate increases in humidity or
(b) humidity above a set-point. The humidity sensor may occasionally
turn the fan ON when environmental conditions change.
MANUAL ON WITH TIMED OFF
The humidity sensing fan has an additional operation feature. For
odor or vapor control, the fan can be energized by cycling the
power switch. Once the fan has been energized in this manner, it
will remain on for 20 minutes.
To manually energize the fan:
1. If fan power switch is already ON, proceed to Step 2; otherwise,
turn power switch ON for more than 1 second.
2. Turn fan power switch OFF for less than 1 second.
3. Turn fan power switch back ON and fan will turn ON.
BB0004
Register your product
online at www.broan.ca
Question and Answer IconNeed help?

Do you have a question about the Broan QTRE100H and is the answer not in the manual?

Broan QTRE100H Specifications

General IconGeneral
BrandBroan
ModelQTRE100H
CategoryFan
LanguageEnglish

Summary

General Safety Warnings

Fire, Electric Shock, and Injury Prevention

Key safety guidelines to reduce the risk of fire, electric shock, or personal injury during operation and installation.

Usage Precautions

Installation and Usage Limitations

Important notes regarding ventilation use, installation in flat ceilings, and protecting the unit from dust and debris.

Product Operation Modes

Humidity Sensor Operation

Explains how the sophisticated humidity sensor responds to rapid humidity increases or levels above a set-point.

Manual Operation with Timed Shutoff

Details the feature allowing manual fan activation for odor control, which remains on for 20 minutes.

Cleaning and Maintenance

Humidity Sensor Cleaning

Procedure for cleaning the humidity sensor using a dry cloth or toothbrush to ensure reliable operation.

Typical Installations

Location Guidelines

Key considerations for choosing the optimal installation location for the humidity sensing fan.

Installation Steps

Mounting Housing to Joist or I-Joist

Instructions for securely mounting the fan housing to structural joists or I-joists using provided tabs and screws.

Mounting Housing Between Framing

Guidance on installing the housing between joists or trusses using hanger bars and mounting channels.

Connecting Ductwork and Wiring

Attach Damper Duct Connector

Steps for attaching the damper/duct connector to the housing, ensuring a flush fit.

Install 4-inch Round Ductwork

Instructions for connecting the 4-inch ductwork and sealing all connections for airtightness.

Wiring Option 1: Auto/Manual Control

Wiring diagram for operating the fan in automatic or manual mode via an ON/OFF switch.

Wiring Option 2: Dual Function Control

Wiring diagram for a 2-function control allowing fan ON/OFF or automatic humidity operation.

Connect Electrical Wiring

Guidance on running house wiring and connecting it to the unit according to diagrams.

Install Grille

Finish Ceiling Installation

Instructions for installing ceiling material around the housing and cutting out the opening.

Attach and Secure Grille

Steps for attaching the grille to the housing by inserting springs into slots and pushing against the ceiling.

Service Parts

Part Identification

List of key numbers and part numbers for replacement components of the humidity sensing fan.

Service Note: Blower Assembly Removal

Specific instructions for safely removing the blower assembly from the unit.

Warranty Information

Three-Year Limited Warranty

Details Broan-NuTone Canada's limited warranty, coverage, exclusions, and duration.

Obtaining Warranty Service

Instructions on how to qualify for and request warranty service, including required information.

Related product manuals