EasyManuals Logo

Brooks Instrument MT3809G User Manual

Brooks Instrument MT3809G
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
1-2
Installation and Operation Manual
X-VA-MT3809G-MT3810G-eng
Part Number: 541B182AAG
December, 2014Models MT3809G & MT3810G
Section 1 Introduction
Table 1-1 Specifications Meter
MT3809MT3809
MT3809MT3809
MT3809
MT3809 ELFMT3809 ELF
MT3809 ELFMT3809 ELF
MT3809 ELF
TFE LinedTFE Lined
TFE LinedTFE Lined
TFE Lined
MT3810MT3810
MT3810MT3810
MT3810
SpecificationsSpecifications
SpecificationsSpecifications
Specifications
Measuring RangeMeasuring Range
Measuring RangeMeasuring Range
Measuring Range See Capacity Tables 1-2A and 1-2B
RangeabilityRangeability
RangeabilityRangeability
Rangeability 10:1 (most sizes)
Metering TubeMetering Tube
Metering TubeMetering Tube
Metering Tube 316/316L (dual certified stainless steel) 316/316L 316/316L
(dual certified stainless steel) (dual certified stainless steel)
Alloy 625, Hastelloy C, Monel K-500, w/Tefzel Lining
Titanium Gr. II Hastelloy C
Flanges and End FittingsFlanges and End Fittings
Flanges and End FittingsFlanges and End Fittings
Flanges and End Fittings 316/316L (dual certified stainless steel) 316/316L 316/316L
(dual certified stainless steel) (dual certified stainless steel)
Alloy 625, Hastelloy C, Titanium Gr. II w/Tefzel Lining
AccuracyAccuracy
AccuracyAccuracy
Accuracy 2%, 1%, 5%, 3%, 2%, 5%,
VDI/VDE class 1.6 VDI/VDE class 4, 2.5 VDI/VDE class 1.6 VDI/VDE class 6
RepeatabilityRepeatability
RepeatabilityRepeatability
Repeatability 0.25% Full Scale 1% Full Scale 0.25% Full Scale 0.25% Full Scale
ScaleScale
ScaleScale
Scale Black increments with white background - Plastic Material
Silver increments with black background - Aluminum Material
ConnectionsConnections
ConnectionsConnections
Connections Weldneck flanges to ANSI B16.5, Flanges to ANSI Weldneck flanges to ANSI
DIN 2527/2635 B16.5, DIN 2527/2635 B16.5, DIN 2527/2635
1/2” to 2”NPT/Rc-Female 1/2” NPT/Rc-Female 1/2” to 2” NPT-Female
1” to 2-1/2” NPT-Male 1” NPT-Male
Flange RatingFlange Rating
Flange RatingFlange Rating
Flange Rating ANSI 1/2” to 4” ANSI 1/2” to 1” ANSI 1/2” to 2” ANSI 1/2” to 2”
150# RF to 600# RF 150# RF to 600# RF 150# RF to 300# RF 150# RF to 300# RF
DIN PN 40 DIN PN40
Standard Flange FinishStandard Flange Finish
Standard Flange FinishStandard Flange Finish
Standard Flange Finish 3.2 - 6.3 Ra
FloatsFloats
FloatsFloats
Floats 316L stainless steel 316L stainless steel/Titanium Hastelloy C-276 (sizes 7,8) 316L stainless steel
Alloy 625, Hastelloy C Monel K-500, PVDF (sizes 10-13)
Titanium Gr. II Hastelloy C
O-ringsO-rings
O-ringsO-rings
O-rings Viton Kalrez 4079 None Viton
Teflon Kalrez 3018 None Teflon
Protection CategoryProtection Category
Protection CategoryProtection Category
Protection Category IP67 / NEMA 4X
Indicator Housing & CoverIndicator Housing & Cover
Indicator Housing & CoverIndicator Housing & Cover
Indicator
Housing & Cover Die cast Aluminum (Alloy 380), epoxy paint, glass window (general purpose)
*Die cast Aluminum (Alloy 380), epoxy paint, glass window (Intrinsic Safe)
Cast 316 stainless steel, glass window (general purpose)
Cast 316 stainless steel, 316 stainless steel hardware, glass window (flameproof)
Pressure/TemperaturePressure/Temperature
Pressure/TemperaturePressure/Temperature
Pressure/Temperature See Pressure/Temperature Tables 1-3A, 1-3B, 1-3C and 1-4
Maximum Fluid TemperatureMaximum Fluid Temperature
Maximum Fluid TemperatureMaximum Fluid Temperature
Maximum Fluid Temperature 420°C/788°F (Refer to Table 1-4) 150°C/270°F 300°C/570°F
Meter DimensionsMeter Dimensions
Meter DimensionsMeter Dimensions
Meter Dimensions Refer to Product Dimensions Figures 1-1, 1-2 and 1-3
Pressure Equipment DirectivePressure Equipment Directive
Pressure Equipment DirectivePressure Equipment Directive
Pressure Equipment Directive Flowmeter complies under Sound Engineering Practices (SEP) or categories I, II, III
(PED) 97/23/EC(PED) 97/23/EC
(PED) 97/23/EC(PED) 97/23/EC
(PED) 97/23/EC
Needle Control ValvesNeedle Control Valves
Needle Control ValvesNeedle Control Valves
Needle Control Valves Sizes 7-12 Sizes 0-5 None Sizes 7-12
Flow ControllersFlow Controllers
Flow ControllersFlow Controllers
Flow Controllers Sizes 7-8 Sizes 0-5 None Sizes 7 & 8
Inductive Alarm Switches *Inductive Alarm Switches *
Inductive Alarm Switches *Inductive Alarm Switches *
Inductive Alarm Switches * 1 or 2 inductive switches (Relay power supply recommended)
TransmitterTransmitter
TransmitterTransmitter
Transmitter 4-20 mA output with HART Rev. 7 communications
Transmitter and InductiveTransmitter and Inductive
Transmitter and InductiveTransmitter and Inductive
Transmitter and Inductive 4-20 mA output with HART Rev. 7 communications and 1 or 2 inductive switches
Alarm Switches*Alarm Switches*
Alarm Switches*Alarm Switches*
Alarm Switches* (Relay power supply recommended)
Transmitter, LCD DisplayTransmitter, LCD Display
Transmitter, LCD DisplayTransmitter, LCD Display
Transmitter, LCD Display 4-20 mA output with HART Rev. 7 communications with digital display
and Inductive Switches*and Inductive Switches*
and Inductive Switches*and Inductive Switches*
and Inductive Switches* plus 1 or 2 inductive switches (Relay power supply recommended)
Transmitter LCD DisplayTransmitter LCD Display
Transmitter LCD DisplayTransmitter LCD Display
Transmitter LCD Display 4-20 mA output with HART Rev. 7 communications and pulse output
Pulse OutputPulse Output
Pulse OutputPulse Output
Pulse Output plus digital display
General Purpose &General Purpose &
General Purpose &General Purpose &
General Purpose &
Intrinsically Safe Power SuppliesIntrinsically Safe Power Supplies
Intrinsically Safe Power SuppliesIntrinsically Safe Power Supplies
Intrinsically Safe Power Supplies
24 Vdc, 110 Vac, 220 Vac
for Transmitterfor Transmitter
for Transmitterfor Transmitter
for Transmitter
Intrinsically Safe Power Supply/RelayIntrinsically Safe Power Supply/Relay
Intrinsically Safe Power Supply/RelayIntrinsically Safe Power Supply/Relay
Intrinsically Safe Power Supply/Relay 24 Vdc, 110 Vac, 220 Vac
for Alarms - Recommended*for Alarms - Recommended*
for Alarms - Recommended*for Alarms - Recommended*
for Alarms - Recommended*
Agency ApprovalsAgency Approvals
Agency ApprovalsAgency Approvals
Agency Approvals Refer to Pages 1-10 to 1-13
Other Approvals*Other Approvals*
Other Approvals*Other Approvals*
Other Approvals* SIL 2 Alarms
EMC ProtectionEMC Protection
EMC ProtectionEMC Protection
EMC Protection The device complies with EU Directive 2004/108/EC,
FCC Part 15, subpart B, Industry Canada, 1 CES-003 Recommendations NE21/NE43
* Inductive Alarm or IS Housing does not apply to MT3809 ELF

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brooks Instrument MT3809G and is the answer not in the manual?

Brooks Instrument MT3809G Specifications

General IconGeneral
BrandBrooks Instrument
ModelMT3809G
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals