Do not locate in insect
infested areas.
Small
insects
getting into the
smoke
detector chamber can cause intermittent alarms.
DON’T place Heat Alarms in any of the following areas:
Bathrooms, shower
rooms or other rooms where the unit may be
triggered by
steam or condensation.
DON’T place Smoke or Heat Alarms in any of the following areas:
Places
where the normal
temperature
can
exceed
45°C or be below 5°C
(e.g.
attics, furnace rooms, directly above ovens or kettles etc.) as the heat/steam
could cause nuisance alarms.
Near a
decorative
object, door, light fitting, window moulding etc., that
may
prevent smoke or heat from entering the Alarm.
S
u
r
f
a
c
e
s
that are
no
r
m
a
ll
y warmer or
c
o
l
d
e
r than the
rest
of
the room (e.g.
a
tt
i
c
hatches). Temperature differences might stop smoke or heat from reaching the uni
t.
Next to or directly
above heaters
or air conditioning
vents,
windows, wall vents
etc.
that can change the direction of airflow.
In very high or awkward
areas
(e.g. over stairwells) where it may be difficult
to
reach the alarm (for testing, hushing or battery replacement).
Locate the unit at least 1m from dimmer controlled lights and wiring
as some
dimmers can cause interference.
Locate unit at least 1.5m and route wiring at least 1m away from
fluorescent
light
fittings as electrical “noise” and/or flickering may affect the unit.
12
B17078-R0-Ei600 SERIE-BROOKS.indd 12 07/12/2010 11:11