eVo5MS07‐11 08/07/2011
InstallationGuide–forusebytheinstaller
Theseinstructionscoverthebasicprinciplestoensurethesatisfactoryinstallationofthestove,
althoughdetailmayneedslightmodificationtosuitparticularlocalsiteconditions.Inallcasesthe
installationmustcomplywithcurrentBuildingRegulations,
LocalAuthorityByelawsandother
specificationsorregulationsastheyaffecttheinstallationofthestove.
ItshouldbenotedthattheBuildingRegulationsrequirementsmaybemetbyadoptingtherelevant
recommendationsgivenincurrentBritishStandardsBSEN15287‐1:2007design,installationand
commissioningofchimneysasan
alternativemeanstoachieveanequivalentlevelofperformanceto
thatobtainedfollowingtheguidancegiveninApprovedDocumentJ.
Werecommendthatyouseektheservicesofaninstallerwhoisconversantwithstoveinstallations
andBuildingRegulations.Theshopwhereyoupurchasedthestoveshouldbeabletohelpinthis
respect.ItisourgeneralpolicytosupplyspecialistFireplaceshopsandtheseshopscanofferanafter
salesserviceandofferadvicewhennecessary.
PleasenotethatitisarequirementunderBroseleyFiresLtd’swarrantysystemthatthe
installationofthestoveiscarriedoutbyaCompetentPersonregisteredwithaGovernment
approvedCompetentPersonsScheme.HETASLtdoperatesuchaSchemeandalisting
oftheir
RegisteredCompetentPersonscanbefoundontheirwebsiteatwww.hetas.co.uk
.
COAlarms:‐
Buildingregulationsrequirethatwheneveraneworreplacementfixedsolidfuelor
wood/biomassapplianceisinstalledinadwellingacarbonmonoxidealarmmustbefittedinthe
sameroomastheappliance.Furtherguidanceontheinstallationofthecarbonmonoxidealarmis
availableinBS
EN50292:2002andfromthealarmmanufacturer’sinstructions.Provisionofan
alarmmustnotbeconsideredasubstituteforeitherinstalling theappliancecorrectlyorensuring
regularservicingandmaintenanceoftheapplianceandchimneysystem.
StovePerformance
IntheUK,thestovehasbee napprovedbyHETASLtdasanintermittentoperatingappliancefor
burningwoodlogsonly.Fortypetestingaprototypesamplewasused.BroseleyFiresconfirmsthe
specificationoftheproductionmodelisnotdifferentincriticaltechnicalaspectstotheprototype
sampletested.
ThenominalfigurestestedunderEN13240forthest oveareasfollows:
eVolution5
HeatOutput 5kW BurningWoodLogs
Weight 100Kg 139KgwithLogStore
FlueGasMassFlow 3.3g/s
FlueGasTemp 215°C