 Error code 0900
Detected irregular power supply for more than 100 times.
 Error code 0A02
Detected a fan failure.
Step Cause Remedy
1
Low-voltage power supply PCB 
failure
Replace the low-voltage power supply 
PCB ASSY. Refer to “1.3.21 Reset 
irregular power supply detection counter 
of low-voltage power supply PCB 
(Function code 88)” in Chapter 5 to reset 
the irregular power supply detection 
counter after the replacement.
2 Main PCB failure Replace the main PCB ASSY.
Note:
The irregular power supply detection error (Error code 0900) of the low-voltage power 
supply PCB occurs when there is a large distortion in the power supply voltage supplied to 
the machine. In this case, if the same power supply is used, the same error might occur 
again even if the low-voltage power supply PCB ASSY is replaced. For this reason, be sure 
to ask the user to rearrange the installation environment.