Effectivity: 916 i A / C24
Edition 0 / Rev. 1
BRP-Rotax Page 3-3
December 01 2023
3.1) EMS
Warning Lamps
HIC
A**)
HIC B**) Effect on
engine
Proposed
action on
ground if
warning
lamp is
persistent
*)
Proposed ac-
tion in flight
*)
0 V Oscillat-
ing
0-12 V
No effect on
engine power,
2 systems
available
Mainte-
nance ac-
tion
required
Flight is possi-
ble to your
destination at
your own
discretion.
Oscillat-
ing
0-12 V
0 V No effect on
engine power,
2 systems
available
Mainte-
nance ac-
tion
required
Flight is possi-
ble to your
destination at
your own
discretion.
0 V 12 V No effect on
engine power,
rely on alter-
nate system
Mainte-
nance ac-
tion
required
Flight is possi-
ble to your
destination at
your own
discretion.
Oscillat-
ing
0-12 V
Oscillat-
ing
0-12 V
No effect on
engine power,
rely on alter-
nate power
supply system
Mainte-
nance ac-
tion
required
Flight is possi-
ble to your
destination at
your own
discretion.
Oscillat-
ing
0-12 V
12 V No effect on
engine power,
rely on alter-
nate system
(oscillating
system)
Mainte-
nance ac-
tion
required
Flight is possi-
ble to your
destination at
your own
discretion.
12 V 0 V No effect on
engine power,
rely on alter-
nate system
Mainte-
nance ac-
tion
required
Flight is possi-
ble to your
destination at
your own
discretion.