Step Procedure
4 Change oil.
5 Remove the top spark plugs and spray all openings with
corrosion inhibiting oil.
6 Turn the propeller several times by hand in direction of the
engine rotation, so that the corrosion inhibiting oil reaches
all necessary points.
7 Install the spark plug in accordance to the Maintenance
Manual.
8 Close all openings on the cold engine, such as exhaust
end pipe, venting tube, air filter etc. against entry of dirt
and humidity.
9 Spray all steel external engine parts with corrosion inhibit-
ing oil.
8.2) Engine back to operation
If preservation (including oil change) took place within a year of
storage, oil renewal will not be necessary. For longer storage
periods repeat preservation annually.
Step Procedure
1 Remove all plugs and caps.
2 Clean spark plugs with plastic brush and solvent.
3 Reinstall.