16 17
Items Supplied
• bruXane b2go dental splint
• Storage box
• Operang instrucons
Check the components for transport damage. If you nd any damage, do not use the b2go but contact our
customer service department.
Before using the b2go, remove all packaging materials and any labels or transport protecon that may be
present.
Product Overview
6
1
2 4 53
1 Motor unit with indicator paper
2 Pressure sensor with indicator paper
3 Metal-reinforced link
4 Pressure sensor with indicator paper
5 Baery unit with indicator paper
6 Storage box
Before Inial Use
The b2go contains a exible metal reinforcement in the anterior region (link between the two sensor
areas) which allows you to adjust your b2go beer to your own personal denon. To do this, hold this
link between your thumb and index nger close to the two sensor surfaces and bend the radius of the link
narrower or wider - depending on whether you want a smaller or wider b2go shape.
Contraindicaons
Read through the following list carefully. If you fall into one of the groups of people listed, do not wear the
b2go or discuss wearing it with your doctor before you do so. If you are unsure, you should always consult
your doctor.
■ b2go must not be used by children (under 18 years of age).
■ b2go may not be used by people with reduced physical, sensory or mental abilies or a lack of experience
and / or knowledge.
■ The following groups of people must not wear the b2go:
ͳ Pregnant and breaseeding women
ͳ Asthmacs
ͳ Epilepcs
■ Do not wear the b2go if you have serious malocclusions and jaw abnormalies that make it impossible
to wear a normal dental splint.
■ Do not wear the b2go if you have large gaps in your teeth with at least two consecuve teeth missing
in the area of the premolars.
■ If your cheek area is too small (e.g. if a boiled sweet causes discomfort in the cheek area), you should
refrain from wearing the b2go because you will nd the splint uncomfortable and bothersome.
■ If you have excessive sensivity to touch (hyperaesthesia) in the cheek area, you should not wear the
b2go.
■ Do not wear the b2go if you know you are allergic to one of the ingredients of silicone.
■ b2go must also not be used:
ͳ if you have serious diculty breathing (e.g. asthma, colds, coughs)
ͳ while you are being treated with a debrillator
ͳ if you are using ammable anaesthecs and gases
ͳ if you are under anaesthec
ͳ in strong electromagnec environments
■ In the case of paents with the following condions, b2go may only be used following explicit prior
consultaon with the doctor treang them:
ͳ in the case of body implants (excluding dental implants), for example heart pacemakers, debrillators,
hearing aids, insulin pumps
ͳ if there is an elevated risk of obstrucve sleep apnoea syndrome
ͳ if there is an elevated risk of Upper Airway Resistance Syndrome (“UARS”)