EasyManuals Logo

Bryan Boilers AB120-W-FDGO User Manual

Bryan Boilers AB120-W-FDGO
4 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
Bryan Steam LLC Leaders Since 1916
783 N. Chili Ave., Peru, Indiana 46970 U.S.A.
Phone:765-473-6651 • Internet:www.bryanboilers.com
Fax: 765-473-3074 • E-mail:bryanboilers@iquest.net
Bryan AB Series Steam & Hot Water Boilers
Specifi cations subject to change without notice. Consult factory to consult on other boiler options.
Form No. 7510 ©2005 Bryan Steam LLC Printed in USA
65-7097
STEAM BOILER DIMENSIONS — inches (cm)
A B C D E F G H I J K L
Boiler Length Width Height Gas Train
Supply
Clearance for Min. Tube Floor to
Model of Outside Over
Overall
Connection
Nozzle
Return Flue Flue
Servicing Removal Flow
Number Jacket Jacket Jacket
Length
(Approx.) 15 psi 150 psi
Conn. Size Location
Burner Clearance Nozzle
AB-90
44
15
/
16
38
1
/
2
77
1
/
4
76 1
1
/
4
4 FLG 3 NPT 1
1
/
2
NPT 10 12 36 24 79
5
/
8
(114.1) (97.79) (196.21) (193.0) (3.2) (10.16) (7.62) (3.81) (25.4) (30.5) (91.4) (60.9) (202.24)
AB-120
54
3
/
16
38
1
/
2
77
1
/
4
85
3
/
8
1
1
/
4
4 FLG 3 NPT 1
1
/
2
NPT 10 12 36 24 79
5
/
8
(137.6) (97.79) (196.21) (216.8) (3.2) (10.16) (7.62) (3.81) (25.4) (30.5) (91.4) (60.9) (202.24)
AB-150
63
1
/
2
38
1
/
2
77
1
/
4
94
3
/
4
1
1
/
2
6 FLG 3 NPT 1
1
/
2
NPT 10 12 36 24 79
5
/
8
(161.3) (97.79) (196.21) (260.7) (3.8) (15.24) (7.62) (3.81) (25.4) (30.5) (91.4) (60.9) (202.24)
AB-200
78
15
/
16
38
1
/
2
77
1
/
4
110 2 6 FLG 3 NPT 1
1
/
2
NPT 10 16
1
/
2
36 24 79
5
/
8
(200.5) (97.79) (196.21) (279.4) (5.1) (15.24) (7.62) (3.81) (25.4) (41.9) (91.4) (60.9) (202.24)
AB-250
94
7
/
16
38
1
/
2
77
1
/
4
125
1
/
2
2 6 FLG 3 NPT 1
1
/
2
NPT 12 15 36 24 79
5
/
8
(239.9) (97.79) (196.21) (318.8) (5.1) (15.24) (7.62) (3.81) (30.5) (38.1) (91.4) (60.9) (202.24)
AB-300
108
13
/
16
38
1
/
2
77
1
/
4
140
15
/
16
2 6 FLG 3 NPT 1
1
/
2
NPT 12 15 36 24 79
5
/
8
(276.4) (97.79) (196.21) (358.0) (5.1) (15.24) (7.62) (3.81) (30.5) (38.1) (91.4) (60.9) (202.24)
WATER BOILER DIMENSIONS — inches (cm)
A B C D E F G H I J K L
Boiler Length Width Height Gas Train
Clearance for Min. Tube Floor to
Model of Outside Over
Overall
Connection
Supply Return Flue Flue
Servicing Removal Flow
Number Jacket Jacket Jacket
Length
(Approx.)
Nozzle Nozzle Size Location
Burner Clearance Nozzle
AB-90
44
15
/
16
34
3
/
4
69
1
/
2
76 1
1
/
4
3-F 3-F 10 12 36 24 74
7
/
8
(114.1) (88.3) (176.5) (193.0) (3.2) (7.6) (7.6) (25.4) (30.5) (91.4) (60.9) (190.2)
AB-120
54
3
/
16
34
3
/
4
69
1
/
2
85
3
/
8
1
1
/
4
3-F 3-F 10 12 36 24 74
7
/
8
(137.6) (88.3) (176.5) (216.8) (3.2) (7.6) (7.6) (25.4) (30.5) (91.4) (60.9) (190.2)
AB-150
63
1
/
2
34
3
/
4
69
1
/
2
94
3
/
4
1
1
/
2
3-F 3-F 10 12 36 24 74
7
/
8
(161.3) (88.3) (176.5) (260.7) (3.8) (7.6) (7.6) (25.4) (30.5) (91.4) (60.9) (190.2)
AB-200
78
15
/
16
34
3
/
4
69
1
/
2
110 2 3-F 3-F 10 16
1
/
2
36 24 74
7
/
8
(200.5) (88.3) (176.5) (279.4) (5.1) (7.6) (7.6) (25.4) (41.9) (91.4) (60.9) (190.2)
AB-250
94
7
/
16
34
3
/
4
69
1
/
2
125
1
/
2
2 3-F 3-F 12 15 36 24 74
7
/
8
(239.9) (88.3) (176.5) (318.8) (5.1) (7.6) (7.6) (30.5) (38.1) (91.4) (60.9) (190.2)
AB-300
108
13
/
16
34
3
/
4
69
1
/
2
140
15
/
16
2 3-F 3-F 12 15 36 24 74
7
/
8
(276.4) (88.31) (176.5) (353.0) (5.1) (7.6) (7.6) (30.5) (38.1) (91.4) (60.9) (190.2)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bryan Boilers AB120-W-FDGO and is the answer not in the manual?

Bryan Boilers AB120-W-FDGO Specifications

General IconGeneral
BrandBryan Boilers
ModelAB120-W-FDGO
CategoryBoiler
LanguageEnglish

Related product manuals