12
Table 3 – Required Charge Adjustment for Indoor Coil Model
F urnace or Fan Coil
Model Number
Outdoor Model Number
288BNV024B
288BNV024A
288BNV025A
288BNV036A 288BNV048A 288BNV060A
CNPV*18** / / / / /
CAP**18** / / / / /
CNP**24 / / / / /
CNPV*19** / / / / /
CAP**24 / / / / /
CSPH*24 / / / / /
CSPH*30** / / / / /
F(E,V)4(A,B,C)NF002 --- --- --- / /
CAP**30 --- / / / /
CNP**30 --- / / / /
CNP**36 --- --- --- / /
F(E,V)4(A,B,C)N(B,F)003 --- --- --- / /
CAP**36 --- --- --- / /
CNP**42 +.50 --- --- / /
CAP**42 +.50 --- --- / /
CSPH*36 / --- --- / /
CSPH*42** / +.75 +.75 / /
CNP**31** / +.75 +.75 / /
CNP**48 / +.75 +.75 --- /
CSPH*48** / +.75 +.75 --- /
CNP**37 / / / / /
CNP**43 / / / / /
CAP**48 / / +.75 --- /
CNP**60 / / / --- ---
CSPH*60 / / / --- ---
F(E,V)4(A,B,C)N(B,F)005 / +.75 +.75 --- /
F(E,V)4(A,B,C)NB006 / / / +2.2 +1.00
CAP**60 / / / +2.2 +1.00
CNP**61 / / / / /
/ = Comb. not allowed
--- = No charge adjust for ID
(53ºC) (56ºC)(47ºC) (50ºC)(42ºC) (44ºC)(36ºC) (39ºC) (58ºC)
Liquid Service Valve Subcooling - For all AHRI listed indoor combinations
CHARGING IN COOLING MODE - 24A, 25
13
9
9.5
10
10.5
11
11.5
12
12.5
14
13.5
Outdoor Ambient Temperature ºF (ºC)
SUBCOOLING TEMPERATURE º F
7.2
5.0
5.3
5.6
5.8
6.1
6.4
6.7
7.0
7.8
7.5
SUBCOOLING TEMPERATURE º C
65 70 75 80 85 90 10595 100
Fig. 19 -- Charging in Cooling Mode 288BNV024A/25
CHARGING IN COOLING MODE - 24B
Fig. 20 -- Charging in Cooling Mode 288BNV024B
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Catalog No: II288B--- 03
Replaces: II288B--- 02