EasyManua.ls Logo

Bryant AIRT PURIFIER User Manual

Bryant AIRT PURIFIER
10 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
Installation, Start--Up, and
Operating Instructions
GAPA
PERFECT AIRT PURIFIER
SIZES 1625 AND 2025
NOTE: Read the entire instruction manual before starting the
install.
This symbol indicates a change since the last issue.
TABLE OF CONTENTS
Page
INTRODUCTION 1..................................
HOW IT WORKS 1..................................
SAFETY CONSIDERATIONS 1........................
APPLICATION CONSIDERATIONS 2..................
INSTALLATION 3--5.................................
START--UP AND OPERATION 6.......................
MAINTENANCE 6..................................
TROUBLESHOOTING 7..............................
SPECIFICATIONS AND DIMENSIONS 8................
WARRANTY 9......................................
INTRODUCTION
Congratulations for selecting the Perfect Airt Purifier for your
home comfort system! The Perfect Airt Purifier is proven to
remove and kill airborne germs and allergens, including viruses,
bacteria, and mold spores. The Perfect Airt Purifier is a
cornerstone of Bryant’s Perfect AirtSolutions for providing
healthier, cleaner air in your home.
HOW IT WORKS
The Perfect Airt Purifier provides extremely high filtration
performance while killing captured contaminants, including
viruses, bacteria, and mold spores. The Perfect Airt Purifier
treats the entire air--stream through a state of the art, three--stage
process, exclusive to Bryant.
In stage one, the particles are electrically charged by a
precision--point ionization array a s they enter the Perfect Airt
Purifier.
In stage two, the charged particles are electrically attracted to
the air purification cartridge, which is located within an electric
field.
In stage three, captured particles are killed by electrical current
flow and ion bombardment.
A06054
Fig. 1 -- GAPA Unit
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service,
maintenance, or use can cause explosion, fire, electrical shock
or other c onditions which may cause personal injury or property
damage. Consult a qualified installer, service a gency, or your
distributor or branch for information or assistance. The
qualified installer or agency must use factory authorized kits or
accessories when modifying this product. Refer to the
individual instructions packaged with the kits or accessories
when installing.
Follow all safety codes. Wear safety glasses and work gloves.
Have fire extinguisher available. Read these instructions
thoroughly and follow all warning or cautions attached to the
unit. Consult local building codes a nd National Electrical Code
(NEC) for special requirements.
It is important to recognize safety information. This is the
safety--alert symbol
. When you see this symbol on the unit
and in instructions or manuals, be alert to the potential for
personal injury. Understand the signal words DANGER,
WARNING, and CAUTION. These words are used with the
safety--alert symbol. DANGER identifies the most serious
hazards which will result in severe personal injury or death.
WARNING signifies hazards which could result in personal
injury or death. CAUTION is used t o identify unsafe practices
which may result in personal injury or product and property
damage. NOTE is used to highlight suggestions which will
result in enhanced installation, reliability, or operation.
Question and Answer IconNeed help?

Do you have a question about the Bryant AIRT PURIFIER and is the answer not in the manual?

Bryant AIRT PURIFIER Specifications

General IconGeneral
Product TypeAir Purifier
BrandBryant
Noise LevelVaries by model
DimensionsVaries by model
WeightVaries by model

Summary

Introduction to Perfect Air Purifier

How the Perfect Air Purifier Works

Safety Considerations for Installation and Use

Application Considerations for HVAC Systems

Air Conditioning Integration

Guidelines for optimal placement and performance with AC systems.

Humidifier Compatibility

Recommendations for installing humidifiers upstream or downstream.

Ductwork Transitions and Turning Vanes

Advice on managing airflow turbulence in ductwork.

Electrical Power Requirements

Specifies power connection via furnace EAC terminals or alternatives.

Installation Procedures

Component Check and Mounting Location

Verify components and identify the optimal mounting position in the return air duct.

Mounting the Purifier Cabinet

Detailed steps for securing the cabinet to the furnace or air handling unit.

Electrical Wiring Connections

Instructions for connecting the purifier's power cord to the HVAC system.

Start-Up and Operation

Checking Purifier Operation

Steps to ensure the purifier powers on and operates with the HVAC system.

Evolution™ Control Configuration

Setting up maintenance reminders via the Evolution™ Control system.

Maximizing Air Purification Performance

Tips for achieving the best filtration results, including fan operation.

Maintenance Requirements

Troubleshooting Guide

Troubleshooting Power Indicator Light

Steps to diagnose why the power indicator light is not illuminating.

Specifications and Dimensions

Limited Warranty Information

Warranty Conditions and Limitations

Details on warranty coverage, conditions, exclusions, and limitations.

Related product manuals