14
* Factory-installed option.
† Field-installed accessory.
NOTES:
1. Not available on single phase (-J voltage code) models. Use field-
installed accessory where available.
2. Requires a field-supplied 24V transformer for each application.
See price pages for details.
3. FDD (Fault Detection and Diagnostic) capability per California
Title 24 section 120.2.
4. Models with RTU Open DDC controls comply with California Title
24 Fault Detection and Diagnostic (FDD).
5. Included with economizer.
6. Sensors used to optimize economizer performance.
7. See application data for assistance.
8. Non-fused disconnect switch cannot be used when unit electrical
rating exceeds:
208-230/1/60 and 208-230/3/60 = 80 amps (FLA).
480/3/60 and 575/3/60 = 80 amps (FLA).
Bryant RTUBuilder automatically selects the amp limitations.
9. Available as a factory-installed option for 04-06 models only.
ITEM OPTION* ACCESSORY
†
GAS HEAT (582K UNITS ONLY)
Low, Medium or High Gas Heat —
Aluminized Heat Exchanger
X
Low, Medium or High Gas Heat —
Stainless Steel Heat Exchanger
X
Propane Conversion Kit X
High Altitude Conversion Kit X
Flue Discharge Deflector X
Flue Shield X
ELECTRIC HEAT (559K UNITS ONLY)
Electric Resistance Heaters X
Single Point Kits X
CABINET
Thru-the-Base electrical or gas-line
connections
XX
Hinged Access Panels X
COIL OPTIONS
Cu/Cu indoor and/or outdoor coils
1
X
Pre-coated outdoor coils
1
X
Premium, E-coated outdoor coils
1
X
HUMIDITY CONTROL
Perfect Humidity™ Dehumidification
System
1
X
CONDENSER PROTECTION
Condenser coil hail guard (louvered
design)
1
XX
CONTROLS
Thermostats, temperature sensors,
and subbases
X
RTU Open Multi-Protocol controller X
Smoke detector (supply and/or
return air)
X
Horn Strobe Annunciator
2
X
Time Guard II compressor delay
control circuit
X
Phase Monitor X X
Condensate Overflow switch X X
ITEM OPTION* ACCESSORY
†
ECONOMIZERS AND OUTDOOR AIR DAMPERS
EconoMi$er
®
IV for electro-mechanical
controls - Non FDD (Standard air leak
damper models)
1, 3, 9
X
EconoMi$er2 for DDC controls (Stan-
dard and Ultra Low Leak air damper
models)
1, 4
XX
EconoMi$er X for electro-mechanical
controls, complies with FDD (Stan-
dard and Ultra Low Leak damper
models)
1, 3, 9
XX
Motorized 2-position outdoor-air
damper
1
XX
Manual outdoor-air damper (25% and
50%)
X
Barometric relief
5
XX
Power exhaust - prop design X
ECOMOMIZER SENSOR AND IAQ DEVICES
Single dry bulb temperature sensors
6
XX
Differential dry bulb temperature
sensors
6
X
Single enthalpy sensors
6
XX
Differential enthalpy sensors
6
X
CO
2
sensor (wall, duct, or unit
mounted)
6
XX
INDOOR MOTOR AND DRIVE
Multiple motor and drive packages X
LOW AMBIENT CONTROL
Winter start kit
7
X
Low Ambient controller to -20°F
(-29°C)
7
X
POWER OPTIONS
Convenience outlet (powered)
1
X
Convenience outlet (unpowered) X
Non-fused disconnect
8
X
ROOF CURBS
Roof curb 14-in. (356 mm) X
Roof curb 24-in. (610 mm) X
Options and accessories