—15—
COMBINATION RATINGS* Continued
* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard: 80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit.
High-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit.
Low-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 17°F (–9°C) db 15°F (–10°C) wb air entering outdoor unit.
Outdoor section/indoor section combination tested in accordance with DOE test procedures for heat pumps. Ratings for other combinations are determined
under DOE computer simulation procedures.
Requires hard shutoff TXV; based on computer simulation.
** TDR is on all furnaces, except 394HAD.
UNIT SIZE-
SERIES
AND
SOUND
RATING
(dBA)
INDOOR
UNIT
ARI STANDARD RATINGS*
Cooling Heating
TC
Seasonal Efficiency SEER
High-Temp Low-Temp Seasonal
Efficiency
HSPF/HSPF
with LSV
Factory-
Supplied
Enhance-
ment
Standard
Rating
Field-Supplied
Accessory‡
TXV
TXV&TDR**
TC COP TC COP
060-A
76
COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA060 55,500 TDR 11.50 61,000 2.84 38,500 2.32 7.20/7.40
CD3(A,B)A060 55,500 TDR 11.50 61,000 2.84 38,500 2.32 7.20/7.40
CC5A/CD5A/CD5BW060 57,000 TDR 12.00 61,000 3.04 39,000 2.44 7.80/8.00
CE3AA060 57,500 TDR 12.00 61,000 3.02 39,000 2.42 7.80/8.00
CJ5A/CK5A/CK5BA060 57,500 TDR 12.00 61,000 2.94 38,500 2.40 7.50
CJ5A/CK5A/CK5BX060 58,500 TDR 12.20 61,000 3.12 38,500 2.48 7.80
CK3BA060 57,500 TDR 12.00 61,000 2.94 38,500 2.40 7.50
COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA060 55,000 TDR 11.50 61,000 2.80 39,000 2.30 7.20/7.40
CD3(A,B)A060 55,000 TDR 11.50 61,000 2.80 39,000 2.30 7.20/7.40
CC5A/CD5A/CD5BW060 56,500 TDR 12.00 61,000 3.02 39,000 2.42 7.50/7.70
CE3AA060 57,500 TDR 12.00 61,000 3.00 39,000 2.42 7.50/7.70
CJ5A/CK5A/CK5BA060 57,500 TDR 11.80 61,000 2.96 38,500 2.38 7.50
CJ5A/CK5A/CK5BX060 58,000 TDR 12.00 61,000 3.10 38,500 2.46 7.80
CK3BA060 57,500 TDR 11.80 61,000 2.96 38,500 2.38 7.50
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA060 55,000 TDR 11.20 61,000 2.80 39,500 2.30 7.20/7.40
CD3(A,B)A060 55,000 TDR 11.20 61,000 2.80 39,500 2.30 7.20/7.40
CC5A/CD5A/CD5BW060 56,500 TDR 11.50 61,000 3.00 39,500 2.40 7.50/7.70
SEER Seasonal Energy Efficiency Ratio LSV Liquid Solenoid Valve
COP Coefficient of Performance TDR Time-Delay Relay
HSPF Heating Seasonal Performance Factor TXV Thermostatic Expansion Valve
TC Total Capacity (Btuh)