EasyManua.ls Logo

Bryant ZONE PERFECT PLUS ZONEBB4KIT - Page 19

Bryant ZONE PERFECT PLUS ZONEBB4KIT
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fig. 17—Single-Stage Furnace
with 1-Speed Heat Pump (Dual Fuel)
A98091
C
O
R
W2
C
R
Y
W
G
Y
SINGLE-STAGE
FURNACE
SINGLE-
SPEED HEAT
PUMP
EQUIPMENT
CONTROLLER
O
B
RH
RC
DEF
DHUM
HUM
W2
W1
G
Y2
Y1
N/A
HEAT STAGE 2
FAN
N/A
COOL/HEAT STAGE 1
N/A
RVS COOLING
DEFROST
N/A
HUMIDIFY
24 VAC HOT
See notes 1, 2, 3, 6, 10, and 11
HUMIDIFIER
(24 VAC)
Fig. 15—1-Stage Furnace with
1-Speed Air Conditioner
A98089
CC
R
Y
W
G
Y
N/A
SINGLE-STAGE
FURNACE
SINGLE-
SPEED AIR
CONDITIONER
EQUIPMENT
CONTROLLER
N/A
24 VAC HOT
N/A
N/A
HUMIDIFY
O
B
RH
RC
W2
W1
G
Y2
Y1
DEF
DHUM
HUM
HUMIDIFIER
(24 VAC)
N/A
HEAT STAGE 1
FAN
N/A
COOL STAGE 1
Fig. 18—1-Stage Furnace with
2-Speed Heat Pump (Dual Fuel)
A98092
TWO-
SPEED HEAT
PUMP
C
O
R
W2
Y2
W3
C
R
Y1
W
G
Y
O
B
RH
SINGLE-STAGE
FURNACE
EQUIPMENT
CONTROLLER
RC
DEF
DHUM
HUM
W2
W1
G
Y2
Y1
N/A
N/A
N/A
HEAT STAGE 3
FAN
DEFROST
HUMIDIFY
RVS COOLING
24 VAC HOT
COOL/HEAT STAGE 2
COOL/HEAT STAGE 1
See notes 1, 2, 3, 4, 6, 7, 8, 9, 10, and 11
HUMIDIFIER
(24 VAC)
Fig. 16—1-Stage Furnace with
2-Speed Air Conditioner
A98090
CC
R
Y1
Y2
W
G
Y
SINGLE-STAGE
FURNACE
TWO-
SPEED AIR
CONDITIONER
EQUIPMENT
CONTROLLER
O
B
RH
RC
W2
W1
G
Y2
Y1
N/A
HEAT STAGE 1
FAN
N/A
24 VAC HOT
N/A
COOL STAGE 2
COOL STAGE 1
See note 4
R
N/A
N/A
HUMIDIFY
DEF
DHUM
HUM
HUMIDIFIER
(24 VAC)
—19—

Other manuals for Bryant ZONE PERFECT PLUS ZONEBB4KIT

Related product manuals