FluidControl
Installation and Operation Instructions
Original instructions
Level- and temperature sensor
Nivotemp NT M-XP
BE100023
05/2017
Bühler Technologies GmbH, Harkortstr. 29, D-40880 Ratingen
Tel. +49 (0) 21 02 / 49 89-0, Fax: +49 (0) 21 02 / 49 89-20
E-Mail: fluidcontrol@buehler-technologies.com
Internet: www.buehler-technologies.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Buhler Nivotemp NT M-XP Series and is the answer not in the manual?

Summary

1 Introduction

2 Safety instructions

2.1 Important advice

Provides crucial advice on device operation, compliance, maintenance, and spare parts.

2.2 General hazard warnings

Outlines general hazards including toxic gases/liquids and electrical voltage risks.

1.4 Model key

4 Setup and connection

4.1 Installation

Guides through the physical installation process, including mounting and float positioning.

4.2 Electrical connections

Explains how to connect the device electrically, referencing plug connectors and supply voltage.

5 Operation and control

5.3 General key functions

5.5 Menu overview

5.6 Changing basic settings

5.6.3 Reallocate switching outputs

5.6.6 Fill level scaling

5.6.7 Assigning the upper limit of the sensor measuring range

5.6.8 Sensor measuring range lower limit assignment

5.6.9 Restore factory settings (Reset)

5.7 Switching outputs

5.7.1 Switching output x: Definition of the switching characteristic

Explains how to define the switching characteristic (Hysteresis/Window) for each output.

5.7.2 Switching output x: Upper switching limit (switching point)

5.7.3 Switching output x: Lower switching limit (switch-back point)

5.7.4 Switching output x: Switch-on delay

5.7.5 Switching output x: Switch-back delay

5.7.6 Switching output x: Testing the switching output

5.7.7 Change status LED display function

5.8 Analogue outputs

5.8.3 Analogue output x: Signal type assignment

5.8.4 Analogue output x: Testing the analogue output

5.9 Diagnostic options

5.9.2 Maximum and minimum fill level

5.9.3 Maximum and minimum temperature

5.9.4 Define switching output to log

7 Service and repair

7.1 Troubleshooting

Provides a table of common problems, their causes, and recommended actions.

Possible errors