  • A
    Austin DavisAug 17, 2025
    Why is too little melt discharged from my Buhnen Melting Machine?
    • B
      Brian RobertsAug 17, 2025
      If too little or no melt is discharged from your Buhnen Melting Machine, the stock temperature might be too low. Try raising the temperature.
  • M
    Miranda PooleAug 20, 2025
    What to do if the nozzle keeps dripping on my Buhnen Melting Machine?
    • K
      Kathy MosesAug 20, 2025
      If the nozzle of your Buhnen Melting Machine drips, it could be due to a partially obstructed or damaged nozzle valve. To resolve this, drain the device, actuate the trigger for about 5 seconds to clear the nozzle, and then clean or replace the nozzle end.
  • L
    Lisa WilsonAug 22, 2025
    How to fix a clogged nozzle system on Buhnen Melting Machines?
    • W
      William LewisAug 22, 2025
      If too little or no melt is discharged from your Buhnen Melting Machine, the nozzle system might be clogged. Try cleaning or replacing the cone nozzle, and if needed, the nozzle end.
  • L
    Lance ScottAug 26, 2025
    What to do if Buhnen Melting Machine discharges too little melt?
    • T
      Timothy SmithAug 26, 2025
      If too little or no melt is discharged from your Buhnen Melting Machine, the operating pressure may be too low. Increase the operating pressure to a maximum of 6 bar.
  • S
    Samuel WalkerAug 28, 2025
    Why is compressed air escaping from the service unit of my Buhnen Melting Machine?
    • B
      Brittany AllenAug 28, 2025
      If compressed air escapes from the service unit of your Buhnen Melting Machine, the connections might not be airtight. Tighten the connections or replace the gaskets to fix this.
  • D
    Derrick SmithAug 30, 2025
    What to check if my Buhnen Melting Machine is not discharging melt?
    • C
      Cody MurphyAug 30, 2025
      If too little or no melt is discharged from your Buhnen Melting Machine, ensure that the compressed-air supply is properly connected and functioning.
  • D
    Derek MartinezSep 2, 2025
    How to fix Buhnen Melting Machines controller that won't turn on or off?
    • E
      Elizabeth YoungSep 2, 2025
      If the controller of your Buhnen Melting Machine cannot be switched on or off, the micro switch at the trigger might be continuously activated or defective. Eliminate any deadlock at the micro switch (sheet metal tongue) or replace the micro switch.
  • K
    Kimberly ChaneySep 5, 2025
    What causes compressed air to escape from the service unit of Buhnen HB 710 HT Melting Machines?
    • E
      Eddie HamiltonSep 5, 2025
      If compressed air is escaping from the service unit of your Buhnen Melting Machine, the sight glass of the water separator may be cracked. Replace the sight glass to resolve this issue.
  • C
    Catherine LawrenceSep 8, 2025
    How to resolve compressed air escaping from Buhnen Melting Machine service unit?
    • B
      brittneycastanedaSep 8, 2025
      If compressed air escapes from the service unit on your Buhnen Melting Machine, the nozzle system may be clogged or damaged. Clean or replace the swirl nozzle, pressure spring, and ball.
  • J
    Jessica VanceSep 12, 2025
    Why is compressed air escaping from the closure cap (11) of my Buhnen Melting Machine?
    • K
      Kimberly SmithSep 12, 2025
      If compressed air escapes from the closure cap of your Buhnen Melting Machine, it could be due to insufficient cover pressure. Try increasing the cover pressure.