EasyManua.ls Logo

Built Right BR115 XW - User Manual

Default Icon
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Pool/Spa Heat Pump
Installation & Operation Manual
Models BR105 XW BR115 XW BR135 XW
BR105 S7 BR115 S7 BR135 S7
BR-40101
Version 2.0

Questions and Answers

  • R
    rswansonSep 4, 2025
    What does PSd mean on Built Right BR115 XW?
    • T
      Tom LopezSep 4, 2025
      If the control display on your Built Right Swimming Pool Heater is flashing “PSd”, it indicates a water sensor malfunction or that the sensor is not connected. It is recommended to call for service.
  • D
    Dustin CainSep 18, 2025
    What does 'PSd' flashing on my Built Right BR115 XW Swimming Pool Heater mean?
    • L
      Lynn GoodwinSep 18, 2025
      If the control display of your Built Right Swimming Pool Heater is flashing 'PSd', it means that there is a water sensor malfunction or the sensor is not connected. Further assistance may be needed.
  • S
    Steven RichSep 16, 2025
    What does 'dSd' flashing on my Built Right Swimming Pool Heater mean?
    • R
      Robert DaughertySep 16, 2025
      If the control display of your Built Right Swimming Pool Heater is flashing 'dSd', it means that there is a defrost sensor malfunction or the sensor is not connected. Further assistance may be needed.
  • J
    Jon WilliamsSep 14, 2025
    What does flashing 'LP' or 'LP3' mean on my Built Right BR115 XW Swimming Pool Heater?
    • J
      James SalasSep 15, 2025
      If your Built Right Swimming Pool Heater control display is flashing “LP” or “LP3”, it indicates low refrigerant or a faulty low-pressure sensor. Further assistance may be needed.
  • B
    Brandy DuncanSep 13, 2025
    What does 'FS5' mean on my Built Right Swimming Pool Heater and how to fix it?
    • K
      Kristi LewisSep 13, 2025
      If your Built Right Swimming Pool Heater displays 'FS5', it means the air temperature is still too cold after five 'FS' signals. Once the air temperature rises above 50°F, press any key on the control. The unit has a built-in one-hour standby mode if no key is pressed. If it remains too cold, the 15-minute FS cycles will resume.
  • M
    Maria HarrisSep 12, 2025
    Why is water leaking from the bottom of my Built Right BR115 XW Swimming Pool Heater?
    • P
      Peter SampsonSep 12, 2025
      Water running out of the bottom of your Built Right Swimming Pool Heater can be due to two reasons. The heater naturally produces up to 3 gallons per hour of water condensing from the evaporator coil. Alternatively, it could indicate an internal water leak. To determine the cause, shut the heater off for several hours but leave the pool pump running. If water continues to leak, it suggests an internal leak, and further assistance may be needed.
  • E
    Emily PeckSep 9, 2025
    Why is my Built Right Swimming Pool Heater flashing 'FS'?
    • J
      Jillian WeeksSep 9, 2025
      If your Built Right Swimming Pool Heater control display is flashing “FS” Or “FS1, FS2, FS3, FS4”, it means the air temperature is too cold for the heater to operate. You should wait until the air temperature warms up to at least 50°F. The heater will automatically cycle on for 2 minutes every 15 minutes to check if the temperature has risen sufficiently.
  • S
    Sarah BlackwellSep 7, 2025
    How to fix Built Right BR115 XW Swimming Pool Heater displaying 'HP, HP3, or HP6'?
    • D
      Dawn McleanSep 8, 2025
      If your Built Right Swimming Pool Heater control displays 'HP, HP3, or HP6', this indicates a water flow restriction, possibly due to a valve restricting flow. Begin by cleaning the pump and filter. Then, adjust the water valves to ensure proper flow. If the problem continues, further assistance may be needed.
  • S
    Shelly SpenceSep 5, 2025
    What to do if my Built Right Swimming Pool Heater control display is flashing 'FLO'?
    • J
      jared96Sep 6, 2025
      If your Built Right Swimming Pool Heater's control display is flashing 'FLO', it indicates that the pool pump is not on, there's a water flow restriction, or the valve position is incorrect. To resolve this, first, turn on the pool pump. Then, ensure that the skimmer basket, pump strainer basket, and pool filter are all clean. Finally, make sure the valves are set properly to allow for adequate water flow.
  • W
    wbaileyAug 21, 2025
    Why is my Built Right BR115 XW Swimming Pool Heater heating slowly?
    • T
      tponceAug 21, 2025
      If your Built Right Swimming Pool Heater is heating the pool slowly, or the pool isn't reaching the desired temperature, several factors could be at play. Check for low or restricted water flow through the heater. Ensure the filter is clean or replace it if necessary. Inspect and clean the pool pump. Adjust the water valves to optimize flow. Other factors include cold weather, an insufficient pump timer setting, not using a pool cover, high wind speed, or a shaded pool area. Using a pool cover and constructing a windbreak can help. Also, consider setting the pool pump timer for a longer run time. If problems persist, call for service.

Summary

Heat Pump Limited Factory Warranty

Introduction to Built Right Pool Heaters

Installation Guide

Location Recommendations

Guidance on optimal placement to prevent water damage and ensure visibility.

Clearances and Airflow Requirements

Specifies minimum space requirements around the unit for proper airflow and ventilation.

Equipment Pad Installation

Instructions for installing the unit on a stable, pitched surface for drainage.

Securing the Unit with Straps

Details on using tie-down straps to secure the unit for stability.

Water Piping Connections

Explains the correct sequence and requirements for connecting the heater to pool plumbing.

Electrical Hook Up and Bonding

Electrical Connection Procedures

Instructions for wiring the heater, emphasizing qualified electricians and correct connections.

Bonding Requirements for Safety

Explains the critical electrical bonding requirement for safety and warranty compliance.

Heat Pump Operation and Control

Turning the Heater On and Off

Step-by-step guide on how to power the heater on and off using the control panel.

Pool and Spa Mode Selection

How to switch between heating modes for pools and spas using the control panel.

Temperature Display and Unit Settings

Information on how the unit displays temperature and how to change between °F and °C.

Keypad Lockout Feature

Instructions for locking and unlocking the control panel keypad and setting a custom code.

Setting Desired Water Temperature

Procedure for adjusting the desired water temperature for pool or spa heating.

Heater Operating Time Recommendations

Guidance on setting the pool pump run time for efficient and effective heating.

Initial Startup Procedure

Steps to follow before the first operation to ensure correct setup and activation.

Understanding the Defrost Cycle

Explanation of the automatic defrost cycle and its display indicator ('FS').

Condensation and Drainage Explanation

Description of normal water drainage from condensation during operation.

Using an External Controller

Instructions for connecting and using an external controller or remote thermostat.

General Maintenance and Winterizing

Cleaning Procedures

Steps for cleaning the evaporator coil, drain holes, and unit housing for optimal performance.

Winterizing the Unit

Procedures for draining the unit to prevent freezing damage in cold climates.

Troubleshooting Common Issues

Troubleshooting Guide

A guide to diagnose and resolve common issues based on control display codes and operational problems.

Service Information and Support

Obtaining Service and Support

Instructions on how to contact the company for assistance, warranty service, and required information.

Overview

This document is the Installation & Operation Manual for Built Right Pool/Spa Heat Pumps, specifically covering models BR105 XW, BR105 S7, BR115 XW, BR115 S7, BR135 XW, and BR135 S7.

Function Description

The Built Right Pool/Spa Heat Pump is designed to heat swimming pools and spas by extracting heat from the surrounding air and transferring it into the water. It operates as a cost-effective method for maintaining a desired water temperature. The system is optimized for outdoor installation and relies on ambient air temperature and humidity for efficient operation.

Important Technical Specifications

Models Covered: BR105 XW, BR105 S7, BR115 XW, BR115 S7, BR135 XW, BR135 S7. Electrical Connection: High Voltage Field Connection 208-230/1/60 or 220-240/1/50. Water Flow Rate:

  • Recommended: 45 GPM (gallons per minute).
  • Minimum: 20 GPM (for BR80 XW, BR105 S7 & BR105 XW, BR115 S7, BR115 XW) and 30 GPM (for BR135 S7 & BR135 XW).
  • Maximum: 70 GPM for all models.
  • A plumbing bypass is required for installations exceeding 70 GPM. Operating Conditions:
  • Ideal or rated condition: 80°F air temperature, 80% relative humidity, and 80°F water temperature.
  • Performance decreases as air temperature and humidity decrease.
  • Not advisable to operate below 45°F ambient air temperature due to insufficient heat in the air. Condensation Production: Typically 3 to 5 gallons of water per hour, depending on ambient air temperature and humidity. Warranty:
  • Applies to models installed in Florida after September 1, 2017.
  • Warranty term begins on the date of purchase or 60 days from manufacture date if no proof of purchase.
  • Warranty form must be submitted within 30 days of purchase.
  • On-Site Labor: 5 years for XW models (BR80 XW, BR105 XW, BR115 XW, BR135 XW); 2 years for S7 models (BR105 S7, BR115 S7, BR135 S7).
  • Parts: 5 years for XW models (BR80 XW, BR105 XW, BR115 XW, BR135 XW); 7 years for S7 models (BR105 S7, BR115 S7, BR135 S7).
  • Warranty is void if the product is repaired or altered by unauthorized persons or agencies.
  • Does not cover damage due to freezing, negligence, abuse, corrosive environments, or acts of God.
  • Requires installation by a licensed professional and operation/maintenance according to the manual. Physical Dimensions (Implied by clearances): Requires at least 4 feet clearance above for air discharge, 6 inches clearance from all walls/restrictions on all sides, and 24 inches access for the control panel.

Usage Features

Installation:

  • Location: Should not be placed where large amounts of water (e.g., roof run-off, sprinklers) can enter. Sprinkler heads should be redirected. Digital control should not face direct sunlight.
  • Equipment Pad: Must be installed on a flat, slightly pitched concrete or fabricated slab for proper drainage of condensation and rainwater. Should be isolated from building foundation to prevent sound/vibration transmission. Located as close as possible to the existing pool pump and filter.
  • Tie Down Straps: Built Right strap kit available upon request for securing the unit to the slab if required by local codes.
  • Water Piping: 2" PVC Unions provided. Piping sequence: Pool Circulation Pump → Filter → Heater → Chlorinator → Pool. Chlorination device must be the last item returning to the pool. Isolation valves required if installed below pool water level (not more than 6 feet below surface or 15 feet above pool level).
  • Electrical Hook Up: Must be performed by a qualified electrician according to local codes. Main power disconnect must be off before opening access panel. Electrical conduit must run up through the base of the unit and connect to the control box. Copper wire and properly sized breaker required.
  • Bonding: All metallic components of the pool structure and equipment (including the heat pump) must be bonded together with a solid copper conductor (not smaller than 8 AWG) to a bonding grid or a copper rod driven into the ground. Warranty is void if not properly bonded.

Operation / Digital Control:

  • Control Panel: Features a digital display with "SET" button and up/down arrows.
  • Turning On/Off: Press "SET" four times until "OFF" appears, then use arrows to select "OFF" or "ON". Pool & Spa lights indicate if the heater is on.
  • Pool/Spa Modes: Equipped with two independent thermostats for pool and spa. Press "SET" until "P_S" appears, then use arrows to switch between "POL" and "SPA".
  • Temperature Display: Pre-set to °F mode. Contact factory for °C mode instructions.
  • Keypad Lockout:
    • Locking: Press "SET" for 5 seconds, enter a two-digit code (default 20) using up/down arrows, then press "SET". "LOC" will display for 3 seconds.
    • Unlocking: Press "SET" for 5 seconds, enter the code, then press "SET".
    • Setting Code: With power off, press and hold "SET" while applying power. Enter desired code.
  • Changing Set Point Temperature: Press "SET" until "POL" or "SPA" is displayed, then use up/down arrows.
  • Heater Operating Time: Pool pump run time needs to be adjusted based on outdoor temperature. May require 24-48 hours of continuous operation initially.
  • Initial Startup: Verify circuit breaker/service disconnect is ON, water is circulating, and pump is activated. Set desired water temperature. Heater starts after a 3-minute delay if set point is higher than actual water temperature.
  • Defrost Cycle: Activates below 48°F ambient air temperature. Unit may shut down and display "FS" until temperature rises.
  • External Controller: Remote wires connect through a rubber plug on the control box. Instructions provided for POOL/SPA Remote, Remote Thermostat, and 3-wire remote controls.

Maintenance Features

General Maintenance:

  • Safety: All power must be disconnected before washing the heater.
  • Airflow: Ensure good airflow through the evaporator. Remove leaves, paper, or debris. Keep shrubs trimmed back.
  • Drainage: Ensure drain holes in the base are free of debris for proper condensate drainage.
  • Evaporator Coil Cleaning: Inspect regularly, especially near oceans/gulfs, for salt or sand buildup. Rinse with fresh water using low pressure (avoid bending coil fins).
  • Housing Cleaning: Made from corrosion-free, UV-resistant polymer. Can be wiped with a cloth or sprayed with fresh water.
  • Cleaning Caution: DO NOT USE ALCOHOL-BASED CLEANERS, as they can damage the polymer housing.
  • Winterizing: In freezing climates, completely drain standing water from the heater and disconnect from pool piping to prevent cracking. Cracked piping due to freezing is not covered under warranty. Not required in non-freezing conditions.

Troubleshooting:

  • A troubleshooting guide is provided for common issues like "HP," "dSd," "PSd," "FLO," "FS," "FS5," "LP," slow heating, and water draining from the bottom.
  • If issues persist, contact the warranty service department at (941) 505-1600.
  • Service must be handled by an Authorized Service Center to maintain warranty validity.
  • When calling for service, provide a detailed description of the problem, model number, serial number, purchase date, and dealer information.
  • Keep a copy of the sales receipt as proof of purchase for in-warranty service.