Bullard CC20 Respiratory Systems provide a continuous flow of air
from a remote air source via airline. The flow of air is delivered
to the respirator wearer through a patented air delivery system.
CC20 Series respirators offer protection from airborne contami-
nants that are not immediately dangerous to life or health (IDLH),
or that do not exceed concentrations allowed by applicable OSHA,
MSHA, EPA, NIOSH or ACGIH regulations and recommendations,
or any other applicable regulations for continuous flow airline
respirators.
CC20 Series airline respirators are approved by NIOSH
(TC-19C-154 Type C). Bullard has determined that these respira-
tors may be used to provide respiratory protection in general
purpose applications, including pharmaceutical manufacturing,
chemical and pesticide handling, tank cleaning, spray painting and
other industrial or agricultural applications in which hazardous
compounds are present.
Bullard hoods are available in 13 different styles and sizes, includ-
ing a loose-fitting facepiece style with a partial facial seal. Bullard
hoods will accommodate limited facial hair without compromising
the level of protection. Facial hair must not interfere with or
protrude under the facial seal on the 20LF or 20LF2 style hoods.
The hood covers are held in place by snap-in replaceable suspen-
sions or, in the case of the loose-fitting facepiece hoods, a sewn-in
elastic suspension. Breathing air is supplied from a breathing tube
connected to the back of the hood.
CC20 Series respirators are compatible with breathing air sources
such as breathing air compressors or Bullard Free-Air
®
Pumps.
Bullard offers the appropriate approved breathing tube, flow
control device and air supply hose to connect the CC20 Series
respirator to these breathing air sources.
CC20 Series respirators are approved by NIOSH for use with
optional Bullard climate control devices. Contact Bullard or its
local authorized distributor for more information about these and
other accessories for CC20 Series respirators.
All Bullard parts must be present and properly assembled to
constitute a NIOSH approved respirator.
For technical assistance, contact Bullard Technical Support at
877-BULLARD (285-5273) or 859-234-6616.
NOTE
Bullard CC20 hoods are also NIOSH approved for cer-
tain PAPR configurations. Please refer to your
Bullard PAPR manual or call Customer Service at
877-BULLARD (285-5273).
Read all instructions and warnings before using these respirators. Failure to follow these instructions could result in death or serious injury.
Save this manual for future reference.
The CC20 Series Airline Respirators are not approved for abrasive blasting.
The CC20 respirator’s air source must supply clean, breathable air, Grade D or better, at all times. The CC20 respirator does not purify air
or filter out contaminants. Connecting the CC20 respirator to a line supplying nitrogen or other harmful gases could cause death or serious
injury.
WARNING
Approval Label ...................................................................................... 2-3
Component Concept - CC20 ................................................................ 4
Warnings and Limitations ................................................................ 5-6
Operations
Protection .................................................................................................... 6
Breathing Air Requirements ....................................................................... 7
Breathing Air Pressure ............................................................................... 7
Breathing Air Supply Hoses and Hose Fittings .......................................... 7
Breathing Air Pressure Table ..................................................................... 8
Respirator Assembly
Adjusting and Installing Headband
in Respirator Hood ...................................................................................... 9
Adjusting and Installing Hard Hat
in Respirator Hood .................................................................................... 10
Installing Breathing Tube Assembly in
Respirator Hood ........................................................................................ 11
Using Climate Control Devices .................................................................. 11
Respirator Use
Donning .......................................................................................................12
Removing .....................................................................................................12
Inspection, Cleaning and Storage
Hood and Headband .................................................................................. 13
Hard Hat .................................................................................................... 14
Breathing Tube ......................................................................................... 14
Flow Control Valve/Climate Control Device .............................................. 14
Air Supply Hoses ....................................................................................... 14
Storage ...................................................................................................... 14
Parts and Accessories ..................................................................... 15-18
Return Authorizations ......................................................................... 19
Table of Contents
Type C Continuous-Flow Class – Approval No. TC-19C-154
CC20 Series Airline Respirator
User Manual

Questions and Answers

Summary

CC20 Series Airline Respirator Approval Label

Cautions and Limitations

Lists essential safety precautions and restrictions for CC20 Airline Respirators.

Protection

Details the respiratory, head, face, eye, and ear protection provided by the CC20 Series respirators.

CC20 Component Concept

Respirator Hood

Describes the variety of styles and materials available for the CC20 Series respirator hoods.

Headband Suspension or Head Protection

Details options for headbands and hard hats compatible with CC20 Series respirator hoods.

Breathing Tube for CC20 Respirators

Lists the different breathing tube models available for CC20 Series respirators.

Flow Control Device

Explains the function and types of flow control devices for CC20 Series respirators.

Air Supply Hose

Describes the hoses used to connect the CC20 Series respirator to the air source.

Safety and Operational Warnings

Cautions & Limitations

Lists essential safety precautions and restrictions for CC20 Airline Respirators.

Operations

Outlines the operational procedures, including respiratory protection, head, face, eye, and ear protection.

CC20 Breathing Air Requirements

Air Quality

Specifies the minimum air quality standards, including oxygen levels and contaminant limits.

Breathing Air Pressure

Explains the importance of monitoring air pressure and the range required for proper airflow.

CC20 Breathing Air Supply Hoses and Hose Fittings

Describes the approved hoses and fittings required for connecting the breathing tube to the air supply.

Breathing Air Pressure Table

CC20 Respirator Assembly

Adjusting and Installing Headband Suspension in Hood

Details how to adjust and install the headband suspension into the respirator hood for a secure fit.

Adjust Crown Straps for Vertical Fit

Explains how to adjust crown straps for optimal vertical fit and wearer comfort.

Adjusting and Installing Hard Hat in Respirator Hood

Installing Breathing Tube Assembly

Installing Breathing Tube Assembly in Hoods (20 BT or RTBT)

Details the process for installing breathing tubes with clamps into hoods.

Installing Breathing Tube Assembly in Loose-Fitting Facepieces

Explains how to install breathing tubes with bayonet connectors into loose-fitting facepieces.

Using Climate Control Devices for CC20 Series Airline Respirators

Instructions for connecting and using optional climate control devices with CC20 Series respirators.

CC20 Respirator Use

Donning the CC20 Respirator

Step-by-step guide on how to put on and secure the CC20 Series respirator before entering a work area.

Removing the CC20 Respirator

Instructions on how to safely remove the CC20 Series respirator after leaving a contaminated area.

Inspection, Cleaning and Storage

Hood and Headband Suspension

Specific guidance on inspecting and cleaning the hood and headband suspension parts.

Component Maintenance

Hard Hat

Instructions for inspecting and cleaning hard hat components used with CC20 respirators.

Breathing Tube

Procedures for inspecting and cleaning the breathing tube to ensure proper function.

Flow Control Valve;Climate Control Device

Details on inspecting and cleaning the flow control and climate control devices.

Air Supply Hoses

Guidelines for inspecting and cleaning the air supply hoses for wear and damage.

Parts and Accessories

Respirator System

Lists complete CC20 Series respirator system kits available for purchase.

Respirator Assemblies

Details various pre-assembled CC20 Series respirator units for different air sources.

Respirator Hoods

Lists different types and styles of respirator hoods available for CC20 Series.

Hood with inner bib, for use with headband suspension

Specific models of hoods with inner bibs designed for use with headband suspensions.

Hood with inner bib, for use with Bullard hard hat

Specific models of hoods with inner bibs designed for use with Bullard hard hats.

Accessory Items for All Hoods

Lists additional accessories applicable to all CC20 Series respirator hoods.

Headband Suspensions and Hard Hats

Details various headband suspensions and hard hat models compatible with CC20 Series.

Accessories for Headband Suspension and Hard Hats

Lists accessories specifically for headband suspensions and hard hats.

Return Authorization

Bullard CC20 Series Specifications

General IconGeneral
BrandBullard
ModelCC20 Series
CategoryRespiratory Product