EasyManuals Logo

Bunn CWT TWIN User Manual

Bunn CWT TWIN
35 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
Page 9
TROUBLESHOOTING (cont.)
PROBLEM
Brew cycle will not start (cont.)
Water is not hot
PROBABLE CAUSE
REMEDY
10737 120800
Refer to Service - ON/OFF Switch
for testing. See page 16
Refer to Service - Start Switch for
testing procedures. See page 20
Refer to Service - Timer for testing
procedures. See page 24 or 25
Refer to Service - Solenoid Valve
for testing procedures. See page
19
(A) Direction of fl ow arrow must
be pointing towards brewer.
(B) Remove the strainer/fl ow con-
trol and check for obstructions.
Clear or replace.
Refer to Service - Tank Heater
Switch for testing procedures.
See page 22
Refer to Service - Limit Thermo-
stat for testing procedures. See
page 16
Refer to Service - Control Ther-
mostat for testing procedures.
See page 15
Refer to Service - Tank Heater for
testing procedures. See page 21
Refer to Service - Recovery
Booster for testing procedures.
See page 18
3. ON/OFF Switch
4. Start Switch
5. Timer
6. Solenoid Valve
7. Water strainer/flow control
(.222 GPM)
1. Tank Heater Switch
2. Limit Thermostat
CAUTION - Do not eliminate or
bypass limit thermostat. Use only
BOM part #29329.1000
3. Control Thermostat
4. Tank Heater
5. Recovery Booster (CWT 2/2,
CWTF 2/2 & 0/6 Only)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bunn CWT TWIN and is the answer not in the manual?

Bunn CWT TWIN Specifications

General IconGeneral
BrandBunn
ModelCWT TWIN
CategoryCoffee Maker
LanguageEnglish

Related product manuals