SWEETENER CALIBRATION (continued)
NOTE: Only perform if you have a 40 ounce or 1000 milliliter container available with 1 ounce
or 1 milliliter increments.
NOTE: Conversion for ml to oz: multiply by .033814.
Conversion for oz to ml: multiply by 29.5735.
1. Press and hold right hidden button until the display
reads CALIBRATE FLOW?.
2. Press the right hidden button again.
3. Continue untill PASSWORD screen appears.
NOTE:
Password is 6601.
continued >
1
2
3
4. Press the + button (UNSWEET) to choose number.
5. Press the >>>> button (CONFIRM NEW BIB) to
move to next number.
Repeat steps 4 and 5 until all four digits are added.
6. Press Done (SWEET).
The SET LANGUAGE screen will appear.
8. Select Yes.
9. Place an empty measuring container under dilution
nozzle. Use the Coca-Cola Universal Measuring Cup
(CCP#12754) - This measurement is in milliliters (ml).
6
7. Press the right hidden button to advance to the
CALIBRATE SWEET screen.
NOTE:
This takes approximately 16 steps.
7
4
5
10. Display will say CONTAINER READY?.
Press Yes (UNSWEET) button.
11. Display will show CAL FLOW SWEET 1.
Press Yes (UNSWEET) button.
10
9
11
8