TROUBLESHOOTING (cont.)
PROBLEM
Weak beverage (cont.)
Dry coffee grounds remain in the
funnel
Brewer is making unusal noises
Cool beverage serving tempera-
ture
PROBABLE CAUSE
REMEDY
4. Funnel Loading
5. Water Temperature
1. Funnel Loading
1. Tank Heater
1. ON/OFF Warmer Switch(s)
2. Warmer Element(s)
The BUNN
®
paper filter must be
centered in the funnel and the
bed of grounds leveled by gentle
shaking.
Place an empty funnel on an empty
dispenser beneath the sprayhead.
Initiate a brew cycle and check the
water temperature immediately
below the sprayhead with a ther-
mometer. The reading should not
be less than 195°F (91˚C). Adjust
the control thermostat to increase
the water temperature. Replace if
necessary.
The BUNN
®
paper filter must be
centered in the funnel and the
bed of grounds leveled by gently
shaking.
Remove and clean lime off the tank
heater. See page 12
Refer to Service - ON/OFF Warmer
Switch for testing procedures. See
page 11
Refer to Service - Warmer Ele-
ment for testing procedures. See
page 14
10860.1 091300