7.5 Electrical Connection
• All electrical work must comply with all relevant wiring regulations and carried out by a qualified
electrician.
• To protect against fire, electric shock and personal injury, do not immerse cord, plug, or water boiler
in water or any other liquid.
• If the supply cord is damaged, it should be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid hazard.
This appliance must be earthed.
The wires in the mains lead are coloured in accordance with the following code:
Means of isolation with at least 3mm contact separation in all poles must be incorporated into fixing of this
appliance.
The fixed wiring insulation must be protected by insulated sleeving having a temperature rating of at least
60˚C.
Supply cords should be oil resistant, sheathed flexible cable not lighter than ordinary polychloroprene or
equivalent elastomer sheathed cord (code 60227 IEC 57).
The appliance is supplied with a terminal block suitable for flexible wires up to 6mm².